Eaton MOV14V385 Metal Oxide Varistor 620 V
Eaton MOV14V385 Metal Oxide Varistor 620 V

Eaton MOV14V385 Metal Oxide Varistor 620 V

Share
MOV14V385: radial leaded metal oxide varistor, 620 V varistor voltage, 505 V working, 1025 V clamp, 320 pF, 128 J.
    • Product Details
    • Download

    Eaton MOV14V385 Metal Oxide Varistor 620 V

    MOV14V385 at a glance: radial leaded metal oxide varistor, 620 V varistor voltage, 505 V working, 1025 V clamp, 320 pF, 128 J.

    Ratings at a Glance

    ParameterValue
    Orderable part numberMOV14V385
    Varistor voltage at 1 mA620 V
    Maximum continuous AC voltage385 Vrms
    Maximum continuous DC voltage505 Vdc
    Clamping voltage1025 V
    Clamping current50 A
    Maximum surge current, 8/20 us4500 A
    Rated power0.6 W
    Typical capacitance at 1 kHz320 pF
    Maximum energy, 10/1000 us128 J
    Maximum body diameter6.5 mm
    Agency recognitioncURus (UL 1449) and TUV
    Package14 mm disc
    MountingRadial, through-hole
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1287

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    What the Numbers Mean

    In a surge event the varistor goes from megohms to ohms in nanoseconds and takes the current the source can deliver. What limits it is the energy in the pulse and the number of pulses, not the peak current alone: the 8/20 test is a single shot.

    The clamp column works out at 1.65 times the varistor voltage: 1025 V at the rated current against 620 V at 1 mA. That ratio is what the downstream part has to survive, not the 620 V figure on the label.

    The disc absorbs 128 J in a 10/1000 us pulse and carries 4500 A in an 8/20 us pulse. Those are single shot figures: the same part will take a fraction of the energy repeatedly.

    At 0.6 W continuous rating the body can sit at the working voltage indefinitely. A 20 mm disc handles roughly 320 pF across the line, which matters on a signal-carrying pair but not on a mains input.

    Within the MOV family this is item 46 of 71 in the Eaton catalogue.

    Series Positioning

    Keep the leads short and do not sleeve them together: the loop area between the two leads is part of the clamping path, and folding them against each other is what keeps the inductance low.

    • The energy rating is for a single 10/1000 microsecond pulse. Repeated surges add up, and a part that absorbs its full rating once will not do it twice without a voltage shift.
    • The derating curve starts at 85 °C for most discs: above that the rated power falls linearly to zero at the maximum temperature.

    Frequently Asked Questions

    Why is the DC rating higher than the AC rating?
    The AC rating is an RMS value, so the peak of the sine is 1.41 times higher. The DC rating is set at that peak plus margin, which is why a 130 Vac part is rated 170 Vdc.

    What happens at end of life?
    A varistor that absorbs more than its rating drifts low in voltage and eventually fails short. That is why a fuse or a thermal element is placed in series with it on mains inputs.

    Can it be used on a DC bus?
    Yes, within the DC rating, but the energy per event is usually larger because there is no zero crossing to help extinguish the follow current. Check the application note before using a mains part on a high-voltage DC bus.