| Parameter | Value |
|---|---|
| Orderable part number | MOV20V175 |
| Varistor voltage at 1 mA | 270 V |
| Maximum continuous AC voltage | 175 Vrms |
| Maximum continuous DC voltage | 225 Vdc |
| Clamping voltage | 455 V |
| Clamping current | 100 A |
| Maximum surge current, 8/20 us | 6500 A |
| Rated power | 1 W |
| Typical capacitance at 1 kHz | 1500 pF |
| Maximum energy, 10/1000 us | 127 J |
| Maximum body diameter | 5 mm |
| Agency recognition | cURus (UL 1449) and TUV |
| Package | 20 mm disc |
| Mounting | Radial, through-hole |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1287 |
Dimensions, recommended pad or hole pattern and the derating curves are
on the data sheet pages; the package line above gives the body size as Eaton states it.
The disc is coated in epoxy and marked with the part number and the varistor voltage. Because the body is the component, the lead spacing and the disc diameter together decide the footprint – there is no separate package to shrink around it.
The clamp column works out at 1.69 times the varistor voltage: 455 V at the rated current against 270 V at 1 mA. That ratio is what the downstream part has to survive, not the 270 V figure on the label.
The disc absorbs 127 J in a 10/1000 us pulse and carries 6500 A in an 8/20 us pulse. Those are single shot figures: the same part will take a fraction of the energy repeatedly.
At 1 W continuous rating the body can sit at the working voltage indefinitely. A 20 mm disc handles roughly 1500 pF across the line, which matters on a signal-carrying pair but not on a mains input.
Within the MOV family this is item 55 of 71 in the Eaton catalogue.
Keep the leads short and do not sleeve them together: the loop area between the two leads is part of the clamping path, and folding them against each other is what keeps the inductance low.
Does the lead spacing matter electrically?
It matters mechanically and for inductance. Wider spacing means a larger loop, which adds inductance in series with the clamp; the disc diameter sets the spacing, so the two choices are linked.
What is the rated power for?
It is the continuous dissipation the disc can take at 85 °C ambient. It matters when the varistor sits at a voltage close to its knee, not during the surge.
Are these parts UL recognised?
Yes, the data sheet lists cURus to UL 1449 and TUV. The file numbers are on the agency page of the data sheet, and they cover the whole family.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd