Eaton MOVGT14V460K Coordinated MOV + GDT, 1800 V
Eaton MOVGT14V460K Coordinated MOV + GDT, 1800 V

Eaton MOVGT14V460K Coordinated MOV + GDT, 1800 V

Share
MOVGT14V460K: integrated MOV / GDT device, 1800 V clamp, 5 pF, 190 J.
    • Product Details
    • Download

    Eaton MOVGT14V460K Coordinated MOV + GDT, 1800 V

    MOVGT14V460K at a glance: integrated MOV / GDT device, 1800 V clamp, 5 pF, 190 J.

    Ratings at a Glance

    ParameterValue
    Orderable part numberMOVGT14V460K
    UL volts385 Vac
    Recommended MCOV460 Vac
    UL MCOV510 Vac
    MOV voltage at 1 mA620(558~682) V
    GDT voltage at 100 V/s1000(800~1200) V
    Platform voltage at 1000 V/usmax. 1100 V
    Peak voltage at 1000 V/usmax. 1800 V
    Withstand count at 2 kV / 1 kA40 shots
    MOV withstand current, 8/20 us6000 A
    Maximum energy, 10/1000 us190 J
    Capacitance at 1 kHz5 pF
    Package14 mm disc
    MountingRadial, through-hole
    Operating temperature-40 °C to +105 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1161

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    The Figures Explained

    This is a mains-input protector, not a board-level one. It is chosen for the first stage ahead of a differential filter, and its platform voltage is what the downstream 1 kV-rated parts have to survive.

    The MOV inside is a 620(558~682) V part and the GDT is a 1000(800~1200) V tube. In series the pair holds the surge at the platform voltage of 1100 V, well under the peak 1800 V it would reach alone at a 1000 V/us edge.

    Withstand is quoted as 40 shots at 2 kV / 1 kA. Because the GDT carries the follow current, the MOV is not eroded by the long tail of the pulse the way a stand-alone varistor is.

    Within the MOVGT family this is item 117 of 160 in the Eaton catalogue.

    Positioning in the Range

    The series combination goes across the input at the first stage, ahead of the filter, with the GDT on the line side. Both devices carry the surge current, so the trace between them has to be as short and as wide as the incoming conductor.

    • The series stack needs the MOV to hold off the line at the end of life as well. If the MOV degrades low in voltage the GDT starts to see the line, which is why the withstand count matters.
    • The capacitance is a few picofarads, which is low enough for a mains input and low enough not to load a signal pair.

    Frequently Asked Questions

    Is the capacitance low enough for a signal line?
    A few picofarads, yes, but this is a mains protector. Its package and its platform voltage are chosen for an input stage, not for a data pair.

    Why put a GDT in series with a MOV?
    The MOV triggers fast and the GDT clamps low. In series the MOV starts the conduction and the GDT carries the current, so the residual voltage is closer to the GDT arc voltage than to the MOV clamp.

    What keeps the GDT from firing on the normal line voltage?
    The MOV holds off the continuous voltage, so the GDT only sees the line when the MOV is conducting. That coordination is what allows the series stack to sit across mains.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products