Eaton MOVGT20V400K MOVGT Hybrid Protector 20 mm
Eaton MOVGT20V400K MOVGT Hybrid Protector 20 mm

Eaton MOVGT20V400K MOVGT Hybrid Protector 20 mm

Share
MOVGT20V400K: integrated MOV / GDT device, 1320 V clamp, 5 pF, 390 J.
    • Product Details
    • Download

    Eaton MOVGT20V400K MOVGT Hybrid Protector 20 mm

    MOVGT20V400K at a glance: integrated MOV / GDT device, 1320 V clamp, 5 pF, 390 J.

    Ratings at a Glance

    ParameterValue
    Orderable part numberMOVGT20V400K
    UL volts385 Vac
    Recommended MCOV400 Vac
    UL MCOV510 Vac
    MOV voltage at 1 mA620(558~682) V
    GDT voltage at 100 V/s600(480~720) V
    Platform voltage at 1000 V/usmax. 1100 V
    Peak voltage at 1000 V/usmax. 1320 V
    Withstand count at 2 kV / 1 kA40 shots
    MOV withstand current, 8/20 us10000 A
    Maximum energy, 10/1000 us390 J
    Capacitance at 1 kHz5 pF
    Package20 mm disc
    MountingRadial, through-hole
    Operating temperature-40 °C to +105 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1161

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    Reading the Data Sheet

    Because the GDT carries the follow current once it has fired, the combination survives repeated surges that would erode a MOV alone. The column to read is the withstand count at 2 kV / 1 kA rather than the single-shot peak current.

    The MOV inside is a 620(558~682) V part and the GDT is a 600(480~720) V tube. In series the pair holds the surge at the platform voltage of 1100 V, well under the peak 1320 V it would reach alone at a 1000 V/us edge.

    Withstand is quoted as 40 shots at 2 kV / 1 kA. Because the GDT carries the follow current, the MOV is not eroded by the long tail of the pulse the way a stand-alone varistor is.

    Within the MOVGT family this is item 154 of 160 in the Eaton catalogue.

    Series Positioning

    The series combination goes across the input at the first stage, ahead of the filter, with the GDT on the line side. Both devices carry the surge current, so the trace between them has to be as short and as wide as the incoming conductor.

    • A GDT has a statistical sparkover. The tolerance in the table is the spread over many units, not the repeatability of one unit.
    • The MOV inside is a disc, so the energy rating follows the disc diameter; the GDT adds current capability, not joules.

    Frequently Asked Questions

    What is the difference between UL volts and MCOV?
    UL volts is the maximum line voltage the part is listed for under UL 1449; MCOV is the maximum continuous operating voltage the MOV element can hold. The two are related but not identical, and both are listed.

    Does the GDT need a separate fuse?
    The follow current is limited by the source impedance and the upstream fuse. Check that the fuse clears the follow current, otherwise the tube keeps conducting after the surge.

    Is the capacitance low enough for a signal line?
    A few picofarads, yes, but this is a mains protector. Its package and its platform voltage are chosen for an input stage, not for a data pair.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products