| Parameter | Value |
|---|---|
| Orderable part number | MOVHE20V140 |
| Varistor voltage at 1 mA | 220 V |
| Maximum continuous AC voltage | 140 Vrms |
| Maximum continuous DC voltage | 180 Vdc |
| Clamping voltage | 360 V |
| Clamping current | 100 A |
| Maximum surge current, 8/20 us | 10000 A |
| Rated power | 1 W |
| Typical capacitance at 1 kHz | 1800 pF |
| Maximum energy, 10/1000 us | 155 J |
| Maximum body diameter | 5 mm |
| Agency recognition | cURus (UL 1449) and TUV |
| Package | 20 mm disc |
| Mounting | Radial, through-hole |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1288 |
Dimensions, recommended pad or hole pattern and the derating curves are
on the data sheet pages; the package line above gives the body size as Eaton states it.
In a surge event the varistor goes from megohms to ohms in nanoseconds and takes the current the source can deliver. What limits it is the energy in the pulse and the number of pulses, not the peak current alone: the 8/20 test is a single shot.
The clamp column works out at 1.64 times the varistor voltage: 360 V at the rated current against 220 V at 1 mA. That ratio is what the downstream part has to survive, not the 220 V figure on the label.
The disc absorbs 155 J in a 10/1000 us pulse and carries 10000 A in an 8/20 us pulse. Those are single shot figures: the same part will take a fraction of the energy repeatedly.
At 1 W continuous rating the body can sit at the working voltage indefinitely. A 20 mm disc handles roughly 1800 pF across the line, which matters on a signal-carrying pair but not on a mains input.
Within the MOVHE family this is item 53 of 71 in the Eaton catalogue.
Keep the leads short and do not sleeve them together: the loop area between the two leads is part of the clamping path, and folding them against each other is what keeps the inductance low.
How do I size the disc diameter?
From the energy, not the current. Estimate the joule content of the surge your source can deliver, add margin for repeated events, and pick the smallest disc that covers it; a larger disc also raises the capacitance across the line.
Why is the DC rating higher than the AC rating?
The AC rating is an RMS value, so the peak of the sine is 1.41 times higher. The DC rating is set at that peak plus margin, which is why a 130 Vac part is rated 170 Vdc.
What happens at end of life?
A varistor that absorbs more than its rating drifts low in voltage and eventually fails short. That is why a fuse or a thermal element is placed in series with it on mains inputs.