| Parameter | Value |
|---|---|
| Orderable part number | MOVHE20V460 |
| Varistor voltage at 1 mA | 750 V |
| Maximum continuous AC voltage | 460 Vrms |
| Maximum continuous DC voltage | 615 Vdc |
| Clamping voltage | 1240 V |
| Clamping current | 100 A |
| Maximum surge current, 8/20 us | 10000 A |
| Rated power | 1 W |
| Typical capacitance at 1 kHz | 530 pF |
| Maximum energy, 10/1000 us | 420 J |
| Maximum body diameter | 7.5 mm |
| Agency recognition | cURus (UL 1449) and TUV |
| Package | 20 mm disc |
| Mounting | Radial, through-hole |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1288 |
Dimensions, recommended pad or hole pattern and the derating curves are
on the data sheet pages; the package line above gives the body size as Eaton states it.
This is a single-shot device in the sense that the joule rating is quoted for one pulse. A surge protector built around a disc survives because the pulses are rare, not because the part is unlimited; the derating curve states how many.
The clamp column works out at 1.65 times the varistor voltage: 1240 V at the rated current against 750 V at 1 mA. That ratio is what the downstream part has to survive, not the 750 V figure on the label.
The disc absorbs 420 J in a 10/1000 us pulse and carries 10000 A in an 8/20 us pulse. Those are single shot figures: the same part will take a fraction of the energy repeatedly.
At 1 W continuous rating the body can sit at the working voltage indefinitely. A 20 mm disc handles roughly 530 pF across the line, which matters on a signal-carrying pair but not on a mains input.
Within the MOVHE family this is item 66 of 71 in the Eaton catalogue.
Mount it with the body clear of the transformer and the bridge rectifier; a disc running at its rated power needs air, and the derating curve assumes it gets some.
Can it be used on a DC bus?
Yes, within the DC rating, but the energy per event is usually larger because there is no zero crossing to help extinguish the follow current. Check the application note before using a mains part on a high-voltage DC bus.
How do I choose between 130 V and 150 V for a 120 V line?
On a 120 V nominal line the steady-state RMS can reach 132 V or more, so a 130 Vac part has no headroom. The 150 V part is the usual choice, and the varistor voltage that comes with it is still below the withstand of most downstream parts.
Does the lead spacing matter electrically?
It matters mechanically and for inductance. Wider spacing means a larger loop, which adds inductance in series with the clamp; the disc diameter sets the spacing, so the two choices are linked.
Shenzhen Gaorunxin Technology Co., Ltd