| Parameter | Value |
|---|---|
| Orderable part number | MOVS4032V485 |
| Working voltage, RMS | 485 Vrms |
| Working voltage, DC | 640 Vdc |
| Varistor voltage at 1 mA | 702-858 V |
| Leakage current at 0.8 Vv | max. 50 uA |
| Clamping voltage, 8/20 us | 1290 V at 10 A |
| Peak current, 8/20 us | 1200 A |
| Maximum energy, 10/1000 us | 65 J |
| Rated power | 0.25 W |
| Typical capacitance at 1 kHz | 60 pF |
| Component thickness | 5.6 mm |
| Package | 4032 |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +85 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1004 |
Dimensions, recommended pad or hole pattern and the derating curves are
on the data sheet pages; the package line above gives the body size as Eaton states it.
Selection follows the same chain as a radial part: continuous voltage first, then varistor voltage, then the energy the transient actually delivers. The clamp column tells you what the downstream circuit sees at the rated current.
The clamp column works out at 1.84 times the varistor voltage: 1290 V at the rated current against 702~858 V at 1 mA. That ratio is what the downstream part has to survive, not the 702~858 V figure on the label.
Standing at 640 V the leakage is at most 50 uA, which is 32 mW of continuous dissipation. Small, but it is why a varistor on a battery rail has to be chosen on leakage and not only on voltage.
At 5.6 mm tall this is the part that has to fit under the enclosure. The 65 J rating and the 1200 A peak come from a body that size, so a lower profile in the same footprint would mean less energy.
Within the MOVS4032 family this is item 29 of 30 in the Eaton catalogue.
The pad is the heatsink. Use the recommended land pattern even when the board is tight; a reduced pad raises the body temperature at the same continuous current.
What is the peak current rating for?
It is the 8/20 microsecond single-shot current the body survives. The energy column is the better guide for a long pulse, because a 10/1000 microsecond waveform delivers far more joules at the same peak.
Why is the capacitance so high?
A 4032 body at 14 Vdc has a large electrode area and a thin dielectric, so the capacitance runs into thousands of picofarads. That is fine on a supply rail and not fine on a data line.
Can two parts be paralleled for more energy?
Only if they are matched, which they are not. The varistor voltage tolerance means one part takes most of the current, so the pair behaves like the weaker one plus a little.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd