Eaton MOVTP14V130T MOVTP Varistor with Thermal Fuse
Eaton MOVTP14V130T MOVTP Varistor with Thermal Fuse

Eaton MOVTP14V130T MOVTP Varistor with Thermal Fuse

Share
MOVTP14V130T: thermally protected metal oxide varistor, 180-220 V varistor voltage, 170 V working, 340 V clamp, 77 J.
    • Product Details
    • Download

    Eaton MOVTP14V130T MOVTP Varistor with Thermal Fuse

    MOVTP14V130T at a glance: thermally protected metal oxide varistor, 180-220 V varistor voltage, 170 V working, 340 V clamp, 77 J.

    Ratings at a Glance

    ParameterValue
    Orderable part numberMOVTP14V130T
    Working voltage, DC170 Vdc
    Working voltage, AC130 Vac
    Varistor voltage at 1 mA180 V to 220 V
    Clamping voltage, 8/20 us340 V at 50 A
    Energy absorption, 10/1000 us77 J
    Rated power0.6 W
    Peak current, 8/20 us6000 A
    Impulse response timeunder 25 ns
    Leakage current at 0.75 V1mAmax. 20 uA
    Pin form3-lead, status contact on the third pin
    Package14 mm disc
    MountingRadial, through-hole
    Operating temperature-40 °C to +105 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1079

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    What the Numbers Mean

    The electrical ratings match an unprotected part of the same disc size, so the selection is unchanged. What changes is the space around the part: the thermal element needs clearance and the third lead needs a route.

    The clamp column works out at 1.7 times the varistor voltage: 340 V at the rated current against 200 V at 1 mA. That ratio is what the downstream part has to survive, not the 200 V figure on the label.

    Standing at 170 V the leakage is at most 20 uA, which is 3.4 mW of continuous dissipation. Small, but it is why a varistor on a battery rail has to be chosen on leakage and not only on voltage.

    The thermal element is the difference from a plain disc of the same rating. If the body overheats the element opens at 0.6 W of continuous overload, before the epoxy and the board around it are damaged.

    The 3-lead form is the mechanical difference: the third pin brings the thermal contact out for monitoring. The electrical table is identical for both.

    Within the MOVTP family this is item 2 of 28 in the Eaton catalogue.

    What This Family Is For

    In the three-lead version the third pin should be treated as a low-voltage signal: it is isolated from the line, but it runs close to it, so keep the creepage of the monitoring track in mind.

    • After the element opens, the circuit has no protection at all. The monitoring signal exists so the board can be taken out of service rather than run unprotected.
    • Agency recognition covers the varistor; the thermal element is part of the same approval and does not need a separate file.

    Frequently Asked Questions

    Is the electrical rating different from an unprotected MOV?
    No, the disc inside is the same. The thermal element adds series resistance of a few milliohms and takes space, but the voltage and energy ratings are unchanged.

    How fast does it trip?
    The thermal path takes seconds, not microseconds. It is designed for the overload that follows a shorted varistor, not for the surge itself – the surge is handled by the disc.

    Does the third lead carry current?
    No. It is a signal contact rated for a monitoring circuit, typically a few milliamps at low voltage. It should not be used to carry the load current.