Eaton MOVTP20V250T Thermal Cut-off Varistor 320 Vdc
Eaton MOVTP20V250T Thermal Cut-off Varistor 320 Vdc

Eaton MOVTP20V250T Thermal Cut-off Varistor 320 Vdc

Share
MOVTP20V250T: thermally protected metal oxide varistor, 351-429 V varistor voltage, 320 V working, 650 V clamp, 240 J.
    • Product Details
    • Download

    Eaton MOVTP20V250T Thermal Cut-off Varistor 320 Vdc

    MOVTP20V250T at a glance: thermally protected metal oxide varistor, 351-429 V varistor voltage, 320 V working, 650 V clamp, 240 J.

    Specification Table

    ParameterValue
    Orderable part numberMOVTP20V250T
    Working voltage, DC320 Vdc
    Working voltage, AC250 Vac
    Varistor voltage at 1 mA351 V to 429 V
    Clamping voltage, 8/20 us650 V at 100 A
    Energy absorption, 10/1000 us240 J
    Rated power1 W
    Peak current, 8/20 us10000 A
    Impulse response timeunder 25 ns
    Leakage current at 0.75 V1mAmax. 20 uA
    Pin form3-lead, status contact on the third pin
    Package20 mm disc
    MountingRadial, through-hole
    Operating temperature-40 °C to +105 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1079

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    Reading the Data Sheet

    The element is thermally coupled to the body, not to the current. That distinction matters: a slow overload that heats the disc without a large current still trips it, which a fuse in series would not see.

    The clamp column works out at 1.67 times the varistor voltage: 650 V at the rated current against 390 V at 1 mA. That ratio is what the downstream part has to survive, not the 390 V figure on the label.

    Standing at 320 V the leakage is at most 20 uA, which is 6.4 mW of continuous dissipation. Small, but it is why a varistor on a battery rail has to be chosen on leakage and not only on voltage.

    The thermal element is the difference from a plain disc of the same rating. If the body overheats the element opens at 1 W of continuous overload, before the epoxy and the board around it are damaged.

    The 3-lead form is the mechanical difference: the third pin brings the thermal contact out for monitoring. The electrical table is identical for both.

    Within the MOVTP family this is item 20 of 28 in the Eaton catalogue.

    Positioning in the Range

    In the three-lead version the third pin should be treated as a low-voltage signal: it is isolated from the line, but it runs close to it, so keep the creepage of the monitoring track in mind.

    • After the element opens, the circuit has no protection at all. The monitoring signal exists so the board can be taken out of service rather than run unprotected.
    • The two-lead and three-lead versions share the electrical table, so the ordering code suffix is the only difference between them.

    Frequently Asked Questions

    Does the third lead carry current?
    No. It is a signal contact rated for a monitoring circuit, typically a few milliamps at low voltage. It should not be used to carry the load current.

    Can it be used on a DC input?
    The varistor part can, within its DC rating. The thermal element does not care about the waveform, so the DC limitation is the same as for any MOV: the follow current has no zero crossing.

    What approvals does it carry?
    The data sheet lists the agency file for the family. The thermal element is covered by the same approval as the varistor inside.