Eaton MP2A-330-R 33.0 uH High-Current Inductor
Eaton MP2A-330-R 33.0 uH High-Current Inductor

Eaton MP2A-330-R 33.0 uH High-Current Inductor

Share
MP2A-330-R: high-current power inductor, 33.0 uH, 0.79 A, Isat 0.79 A, DCR 476 mOhm.
    • Product Details
    • Download

    Eaton MP2A-330-R 33.0 uH High-Current Inductor

    MP2A-330-R at a glance: high-current power inductor, 33.0 uH, 0.79 A, Isat 0.79 A, DCR 476 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberMP2A-330-R
    Inductance33.0 uH ±20%
    DCR maximum @ +25 °C476 mOhm
    Irms (DC, 40 °C rise)0.79 A
    Isat0.79 A
    Volt-time rating5.32 V-us
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4112

    Mechanical Drawing

    MP2A-330-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4112: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    What the Numbers Mean

    The part is built around a distributed-gap core: the energy is stored through the volume of the magnetic material rather than in a single discrete gap, which is what produces the gradual rolloff and the low fringing field. Copper loss and core loss are traded against each other in the winding and body proportions.

    At 0.79 A the winding dissipates about 0.297 W in copper, using the 476 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 0.79 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    The volt-time rating is 5.32 V-us: the applied volt-second product that produces a defined core loss. Exceed it and the core heats faster than the copper loss alone would suggest.

    Within the MP2A family this is value 12 of 16, in a range that runs from 0.47 to 100 uH.

    Positioning in the Range

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: mobile phones; tablets and e-readers; gps systems; battery power devices; notebook and laptop power.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    Is the part shielded?
    The molded body encloses the winding, so the external field is small enough to place parts side by side on a multiphase rail.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.

    Is the part shielded?
    The molded body encloses the winding, so the external field is small enough to place parts side by side on a multiphase rail.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products