Eaton MP2A-4R7-R 4.7 uH Shielded Inductor 117 mOhm
Eaton MP2A-4R7-R 4.7 uH Shielded Inductor 117 mOhm

Eaton MP2A-4R7-R 4.7 uH Shielded Inductor 117 mOhm

Share
MP2A-4R7-R: high-current power inductor, 4.7 uH, 1.6 A, Isat 1.81 A, DCR 117 mOhm.
    • Product Details
    • Download

    Eaton MP2A-4R7-R 4.7 uH Shielded Inductor 117 mOhm

    MP2A-4R7-R at a glance: high-current power inductor, 4.7 uH, 1.6 A, Isat 1.81 A, DCR 117 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberMP2A-4R7-R
    Inductance4.7 uH ±20%
    DCR maximum @ +25 °C117 mOhm
    Irms (DC, 40 °C rise)1.6 A
    Isat1.81 A
    Volt-time rating2.64 V-us
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4112

    Dimensions and Pad Layout

    MP2A-4R7-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4112: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    Reading the Data Sheet

    This is a surface-mount power inductor for DC-DC conversion. Its two limiting numbers are Irms, which sets the thermal ceiling, and Isat, which sets the current at which inductance has fallen by a defined percentage – both are on the data sheet row and both matter at different points in the load profile.

    At 1.6 A the winding dissipates about 0.3 W in copper, using the 117 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 1.81 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    The volt-time rating is 2.64 V-us: the applied volt-second product that produces a defined core loss. Exceed it and the core heats faster than the copper loss alone would suggest.

    Within the MP2A family this is value 6 of 16, in a range that runs from 0.47 to 100 uH.

    Where This Series Fits

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: mobile phones; tablets and e-readers; gps systems; battery power devices; notebook and laptop power.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    What is the difference between Irms and Isat?
    Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.

    What is the difference between Irms and Isat?
    Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products