| Parameter | Value |
|---|---|
| Orderable part number | MP2A-8R2-R |
| Inductance | 8.2 uH ±20% |
| DCR maximum @ +25 °C | 167 mOhm |
| Irms (DC, 40 °C rise) | 1.34 A |
| Isat | 1.54 A |
| Volt-time rating | 3.15 V-us |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4112 |

Drawing reproduced from Eaton Technical Data 4112: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
The part is built around a distributed-gap core: the energy is stored through the volume of the magnetic material rather than in a single discrete gap, which is what produces the gradual rolloff and the low fringing field. Copper loss and core loss are traded against each other in the winding and body proportions.
At 1.34 A the winding dissipates about 0.3 W in copper, using the 167 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.
Saturation is reached at 1.54 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.
The volt-time rating is 3.15 V-us: the applied volt-second product that produces a defined core loss. Exceed it and the core heats faster than the copper loss alone would suggest.
Within the MP2A family this is value 8 of 16, in a range that runs from 0.47 to 100 uH.
The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.
Is the part shielded?
The molded body encloses the winding, so the external field is small enough to place parts side by side on a multiphase rail.
What is the difference between Irms and Isat?
Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.
Is the part shielded?
The molded body encloses the winding, so the external field is small enough to place parts side by side on a multiphase rail.