Eaton MPI2520R1-R47-R 0.47 uH High-Current Inductor
Eaton MPI2520R1-R47-R 0.47 uH High-Current Inductor

Eaton MPI2520R1-R47-R 0.47 uH High-Current Inductor

Share
MPI2520R1-R47-R: high-current power inductor, 0.47 uH, 4.5 A, Isat 4.8 A, DCR 20 mOhm.
    • Product Details
    • Download

    Eaton MPI2520R1-R47-R 0.47 uH High-Current Inductor

    MPI2520R1-R47-R at a glance: high-current power inductor, 0.47 uH, 4.5 A, Isat 4.8 A, DCR 20 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberMPI2520R1-R47-R
    Inductance0.47 nH ±20%
    DCR maximum @ +25 °C20 mOhm
    Irms (DC, 40 °C rise)4.5 A
    Isat4.8 A
    K-factor2310
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10199

    Dimensions and Pad Layout

    MPI2520R1-R47-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10199: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    What the Numbers Mean

    The part is built around a distributed-gap core: the energy is stored through the volume of the magnetic material rather than in a single discrete gap, which is what produces the gradual rolloff and the low fringing field. Copper loss and core loss are traded against each other in the winding and body proportions.

    At 4.5 A the winding dissipates about 0.405 W in copper, using the 20 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 4.8 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the MPI2520R1 family this is value 1 of 9, in a range that runs from 0.47 to 10 uH.

    Series Positioning

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: mobile/smart phones; handheld/mobile equipment; digital cameras; media players; mp3 players.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Shenzhen Gaorunxin Technology Co., Ltd