Eaton MPI4015V2-6R8-R 6.8 uH Shielded Inductor 207 mOhm
Eaton MPI4015V2-6R8-R 6.8 uH Shielded Inductor 207 mOhm

Eaton MPI4015V2-6R8-R 6.8 uH Shielded Inductor 207 mOhm

Share
MPI4015V2-6R8-R: high-current power inductor, 6.8 uH, 2 A, Isat 172 A, DCR 207 mOhm.
    • Product Details
    • Download

    Eaton MPI4015V2-6R8-R 6.8 uH Shielded Inductor 207 mOhm

    MPI4015V2-6R8-R at a glance: high-current power inductor, 6.8 uH, 2 A, Isat 172 A, DCR 207 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberMPI4015V2-6R8-R
    Inductance6.8 uH ±20%
    DCR maximum @ +25 °C207 mOhm
    Irms (DC, 40 °C rise)2 A
    Isat172 A
    SRF typical21 MHz
    K-factor609
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10651

    Outline Drawing

    MPI4015V2-6R8-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10651: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    The Figures Explained

    This is a surface-mount power inductor for DC-DC conversion. Its two limiting numbers are Irms, which sets the thermal ceiling, and Isat, which sets the current at which inductance has fallen by a defined percentage – both are on the data sheet row and both matter at different points in the load profile.

    At 2 A the winding dissipates about 0.828 W in copper, using the 207 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 172 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the MPI4015V2 family this is value 11 of 12, in a range that runs from 0.22 to 10 uH.

    Where This Series Fits

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: handheld/mobile devices; portable media players; notebook/netbook/laptop regulators; tablets/smartbooks; battery operated devices.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    What is the difference between Irms and Isat?
    Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.

    What is the difference between Irms and Isat?
    Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products