| Parameter | Value |
|---|---|
| Orderable part number | MPI4020V2-R33-R |
| Inductance | 0.33 nH ±20% |
| DCR maximum @ +25 °C | 7.5 mOhm |
| Irms (DC, 40 °C rise) | 9.5 A |
| Isat | 12 A |
| SRF typical | 9 MHz |
| K-factor | 113 |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10651 |

Drawing reproduced from Eaton Technical Data 10651: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
The part is built around a distributed-gap core: the energy is stored through the volume of the magnetic material rather than in a single discrete gap, which is what produces the gradual rolloff and the low fringing field. Copper loss and core loss are traded against each other in the winding and body proportions.
At 9.5 A the winding dissipates about 0.677 W in copper, using the 7.5 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.
Saturation is reached at 12 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.
Within the MPI4020V2 family this is value 3 of 16, in a range that runs from 0.1 to 22 uH.
The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.
How much inductance is left at rated current?
The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.
Why are there two DCR columns?
Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.
What is the difference between Irms and Isat?
Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.
Shenzhen Gaorunxin Technology Co., Ltd