Eaton MPIA2512V2-R68-R 0.68 uH Shielded Power Inductor
Eaton MPIA2512V2-R68-R 0.68 uH Shielded Power Inductor

Eaton MPIA2512V2-R68-R 0.68 uH Shielded Power Inductor

Share
MPIA2512V2-R68-R: automotive power inductor, 0.68 uH , 3.4 A Irms, Isat 6 A, DCR 29 mOhm.
    • Product Details
    • Download

    Eaton MPIA2512V2-R68-R 0.68 uH Shielded Power Inductor

    MPIA2512V2-R68-R at a glance: automotive power inductor, 0.68 uH , 3.4 A Irms, Isat 6 A, DCR 29 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberMPIA2512V2-R68-R
    Inductance0.68 uH
    DCR typical @ +20 °C29 mOhm
    DCR maximum @ +20 °C35 mOhm
    Irms (DC, 40 °C rise)3.4 A
    Isat6 A
    SRF typical70 MHz
    K-factor3633
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10650

    Dimensions and Pad Layout

    MPIA2512V2-R68-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10650: outline with
    rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    The part is built for automotive DC-DC stages: AEC-Q200 qualified, shielded, and characterised with both typical and maximum DCR so the loss budget can be built on either figure.

    At 3.4 A the winding dissipates about 0.335 W in copper using the typical DCR of 29 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 12.2 uJ at the saturation point, which is the energy available to bridge a load step.

    Self-resonance is 70 MHz typical. Keep the operating band, and the harmonics that carry energy, below it.

    The K-factor of 3633 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.

    Within the MPIA2512V2 family this is value 3 of 7, in a range from 0.33 uH to 3.3 uH.

    Positioning in the Range

    The MPIA family is the automotive miniature power range: AEC-Q200 qualified, low profile, in sizes from 2 mm to 4 mm, with both typical and maximum DCR quoted for every row.

    • DCR is quoted at +20 °C; copper rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps, interior lighting and led lighting; doors, window lift and seat control.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three numbers, three checks.

    Frequently Asked Questions

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL.

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.