Eaton MPIA4015V2-R68-R 0.68 uH Power Inductor, 6.8 A
Eaton MPIA4015V2-R68-R 0.68 uH Power Inductor, 6.8 A

Eaton MPIA4015V2-R68-R 0.68 uH Power Inductor, 6.8 A

Share
MPIA4015V2-R68-R: automotive power inductor, 0.68 uH , 6.8 A Irms, Isat 8 A, DCR 16 mOhm.
    • Product Details
    • Download

    Eaton MPIA4015V2-R68-R 0.68 uH Power Inductor, 6.8 A

    MPIA4015V2-R68-R at a glance: automotive power inductor, 0.68 uH , 6.8 A Irms, Isat 8 A, DCR 16 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberMPIA4015V2-R68-R
    Inductance0.68 uH
    DCR typical @ +20 °C16 mOhm
    Irms (DC, 40 °C rise)6.8 A
    Isat8 A
    SRF typical19 MHz
    K-factor81
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10652

    Dimensions and Pad Layout

    MPIA4015V2-R68-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10652: outline with
    rated mm dimensions, pad layout and marking.

    The Figures Explained

    Power inductors in this family are chosen on three numbers: inductance for ripple, saturation current for the transient, and DCR for loss. The data sheet row gives all three against defined test conditions.

    At 6.8 A the winding dissipates about 0.74 W in copper using the typical DCR of 16 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 21.8 uJ at the saturation point, which is the energy available to bridge a load step.

    Self-resonance is 19 MHz typical. Keep the operating band, and the harmonics that carry energy, below it.

    The K-factor of 81 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.

    Within the MPIA4015V2 family this is value 5 of 12, in a range from 0.22 uH to 10 uH.

    What This Family Is For

    The MPIA family is the automotive miniature power range: AEC-Q200 qualified, low profile, in sizes from 2 mm to 4 mm, with both typical and maximum DCR quoted for every row.

    • DCR is quoted at +20 °C; copper rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting; doors, window lift and seat control.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three numbers, three checks.

    Frequently Asked Questions

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL.

    Is the part shielded?
    The molded body encloses the winding, so the external field is small enough for dense layouts.

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.