Eaton MPIA4040R1-R68-R 0.68 uH Inductor, Isat 9 A
Eaton MPIA4040R1-R68-R 0.68 uH Inductor, Isat 9 A

Eaton MPIA4040R1-R68-R 0.68 uH Inductor, Isat 9 A

Share
MPIA4040R1-R68-R: automotive power inductor, 0.68 uH , 3.3 A Irms, Isat 9 A, DCR 51 mOhm.
    • Product Details
    • Download

    Eaton MPIA4040R1-R68-R 0.68 uH Inductor, Isat 9 A

    MPIA4040R1-R68-R at a glance: automotive power inductor, 0.68 uH , 3.3 A Irms, Isat 9 A, DCR 51 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberMPIA4040R1-R68-R
    Inductance0.68 uH
    DCR typical @ +20 °C51 mOhm
    Irms (DC, 40 °C rise)3.3 A
    Isat9 A
    K-factor461
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10230

    Outline Drawing

    MPIA4040R1-R68-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10230: outline with
    rated mm dimensions, pad layout and marking.

    Reading the Data Sheet

    This is a surface-mount power inductor with a distributed-gap core. The energy is stored through the volume of the magnetic material rather than a single gap, which produces the gradual rolloff and keeps the fringing field small.

    At 3.3 A the winding dissipates about 0.555 W in copper using the typical DCR of 51 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 27.5 uJ at the saturation point, which is the energy available to bridge a load step.

    The K-factor of 461 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.

    Within the MPIA4040R1 family this is value 6 of 11, in a range from 0.09 uH to 4.7 uH.

    Where This Series Fits

    The MPIA family is the automotive miniature power range: AEC-Q200 qualified, low profile, in sizes from 2 mm to 4 mm, with both typical and maximum DCR quoted for every row.

    • DCR is quoted at +20 °C; copper rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: body electronics – central body control module – vehicle access control system – headlamps, tail lamps and interior lighting – door control; chassis and safety electronics – airbag control unit.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three numbers, three checks.

    Frequently Asked Questions

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    What is the difference between Irms and Isat?
    Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL.