Eaton MPIA4040R3-150-R 15 uH Shielded Power Inductor
Eaton MPIA4040R3-150-R 15 uH Shielded Power Inductor

Eaton MPIA4040R3-150-R 15 uH Shielded Power Inductor

Share
MPIA4040R3-150-R: automotive power inductor, 15 uH , 1.3 A Irms, Isat 3 A, DCR 285 mOhm.
    • Product Details
    • Download

    Eaton MPIA4040R3-150-R 15 uH Shielded Power Inductor

    MPIA4040R3-150-R at a glance: automotive power inductor, 15 uH , 1.3 A Irms, Isat 3 A, DCR 285 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberMPIA4040R3-150-R
    Inductance15 uH
    DCR typical @ +20 °C285 mOhm
    Irms (DC, 40 °C rise)1.3 A
    Isat3 A
    K-factor213
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10230

    Dimensions and Pad Layout

    MPIA4040R3-150-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10230: outline with
    rated mm dimensions, pad layout and marking.

    How to Read These Ratings

    A molded automotive power inductor with a soft saturation curve: as current rises the inductance droops instead of collapsing, so a converter keeps control through a load step. The body is molded around the winding, which contains the field.

    At 1.3 A the winding dissipates about 0.482 W in copper using the typical DCR of 285 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 67.5 uJ at the saturation point, which is the energy available to bridge a load step.

    The K-factor of 213 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.

    Within the MPIA4040R3 family this is value 10 of 10, in a range from 0.22 uH to 15 uH.

    Positioning in the Range

    The MPIA family is the automotive miniature power range: AEC-Q200 qualified, low profile, in sizes from 2 mm to 4 mm, with both typical and maximum DCR quoted for every row.

    • DCR is quoted at +20 °C; copper rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: body electronics – central body control module – vehicle access control system – headlamps, tail lamps and interior lighting – door control; chassis and safety electronics – airbag control unit.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three numbers, three checks.

    Frequently Asked Questions

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL.

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.