Eaton MPIA4040R3-3R3-R 3.3 uH Shielded Power Inductor
Eaton MPIA4040R3-3R3-R 3.3 uH Shielded Power Inductor

Eaton MPIA4040R3-3R3-R 3.3 uH Shielded Power Inductor

Share
MPIA4040R3-3R3-R: automotive power inductor, 3.3 uH , 3 A Irms, Isat 6.6 A, DCR 60 mOhm.
    • Product Details
    • Download

    Eaton MPIA4040R3-3R3-R 3.3 uH Shielded Power Inductor

    MPIA4040R3-3R3-R at a glance: automotive power inductor, 3.3 uH , 3 A Irms, Isat 6.6 A, DCR 60 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberMPIA4040R3-3R3-R
    Inductance3.3 uH
    DCR typical @ +20 °C60 mOhm
    Irms (DC, 40 °C rise)3 A
    Isat6.6 A
    K-factor432
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10230

    Dimensions and Pad Layout

    MPIA4040R3-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10230: outline with
    rated mm dimensions, pad layout and marking.

    The Figures Explained

    This is a surface-mount power inductor with a distributed-gap core. The energy is stored through the volume of the magnetic material rather than a single gap, which produces the gradual rolloff and keeps the fringing field small.

    At 3 A the winding dissipates about 0.54 W in copper using the typical DCR of 60 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 71.9 uJ at the saturation point, which is the energy available to bridge a load step.

    The K-factor of 432 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.

    Within the MPIA4040R3 family this is value 6 of 10, in a range from 0.22 uH to 15 uH.

    Positioning in the Range

    The MPIA family is the automotive miniature power range: AEC-Q200 qualified, low profile, in sizes from 2 mm to 4 mm, with both typical and maximum DCR quoted for every row.

    • DCR is quoted at +20 °C; copper rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: body electronics – central body control module – vehicle access control system – headlamps, tail lamps and interior lighting – door control; chassis and safety electronics – airbag control unit.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three numbers, three checks.

    Frequently Asked Questions

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL.

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.