| Parameter | Value |
|---|---|
| Orderable part number | MTA3V3944S-1R5-R |
| Inductance | 1.5 uH |
| FLL minimum (at Isat) | 0.84 uH |
| DCR typical @ +20 °C | 0.21 mOhm |
| DCR maximum @ +20 °C | 0.24 mOhm |
| Irms (DC, 40 °C rise) | 140 A |
| Isat | 205 A |
| SRF typical | 23.4 MHz |
| K-factor | 14.8 |
| Mounting | Through-hole |
| Operating temperature | -55 °C to +155 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1530 |

Drawing reproduced from Eaton Technical Data ELX1530: outline with
rated mm dimensions, pad layout and marking.
Molded construction with a distributed gap gives a soft saturation curve and a low DCR for the current rating. The part is aimed at high-current DC-DC stages on boards that are wave or selectively soldered.
At 140 A the winding dissipates about 4.12 W in copper using the typical DCR of 0.21 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.
The core stores about 31519 uJ at the saturation point, which is the energy available to bridge a load step.
Self-resonance is 23.4 MHz typical. Keep the operating band, and the harmonics that carry energy, below it.
The K-factor of 14.8 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.
Within the MTA3V3944S family this is value 1 of 2, in a range from 1.5 uH to 2.2 uH.
The MTA family is the molded through-hole high-current range: AEC-Q200 qualified, with two Irms and two Isat columns for thermal and transient checks.
Is the body shielded?
The molding encloses the winding, so the external field is small.
Is the body shielded?
The molding encloses the winding, so the external field is small.
Why through-hole for this current level?
The leads carry heat into the board copper and the body is not limited by reflow standoff, which is how the part reaches its current rating.