Eaton POEA1FB1V3W2X5 PoE Flyback Transformer, 3 W
Eaton POEA1FB1V3W2X5 PoE Flyback Transformer, 3 W

Eaton POEA1FB1V3W2X5 PoE Flyback Transformer, 3 W

Share
POEA1FB1V3W2X5: PoE transformer, 1:0.146:0.146:0.313 turns ratio, 3 W.
    • Product Details
    • Download

    Eaton POEA1FB1V3W2X5 PoE Flyback Transformer, 3 W

    POEA1FB1V3W2X5 at a glance: PoE transformer, 1:0.146:0.146:0.313 turns ratio, 3 W.

    Key Specifications

    ParameterValue
    Orderable part numberPOEA1FB1V3W2X5
    Output power3 W
    OCL (primary inductance)155 uH
    SCL (saturated inductance)2.8 uH
    Isat0.8 A
    Turns ratio pri : sec : aux1:0.146:0.146:0.313
    Output configuration(2) x 5.0 V
    DCR primary350 mOhm
    DCR secondary 150 mOhm
    DCR secondary 2150 mOhm
    DCR auxiliary320 mOhm
    Schematic variantWinding arrangement 1
    Package15.2 x 12.5 x 11.6 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1266

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1266; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    A PoE PD flyback transformer takes the 37 to 57 V on the cable and steps it down to the rails the powered device needs, with the isolation barrier in between. The turns ratio, the primary inductance and the saturation current are set by the controller and the power level, not chosen freely.

    At the 0.8 A saturation point the primary stores about 49.6 uJ, which sets the maximum energy per switching cycle.

    Within the POEA1FB1V3W2X5 family this is item 1 of 1 in the Eaton catalogue.

    Series Positioning

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    Is the isolation reinforced?
    The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.

    Is the isolation reinforced?
    The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.

    Can I use a forward part in a flyback design?
    No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.