Eaton POEA1FB1V7W1X5 Flyback Transformer 1:0.125:0.208
Eaton POEA1FB1V7W1X5 Flyback Transformer 1:0.125:0.208

Eaton POEA1FB1V7W1X5 Flyback Transformer 1:0.125:0.208

Share
POEA1FB1V7W1X5: PoE transformer, 1:0.125:0.208 turns ratio, 7 W.
    • Product Details
    • Download

    Eaton POEA1FB1V7W1X5 Flyback Transformer 1:0.125:0.208

    POEA1FB1V7W1X5 at a glance: PoE transformer, 1:0.125:0.208 turns ratio, 7 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberPOEA1FB1V7W1X5
    Output power7 W
    OCL (primary inductance)253 uH
    SCL (saturated inductance)7.5 uH
    Isat0.45 A
    Turns ratio pri : sec : aux1:0.125:0.208
    Output configuration(1) x 5.0 V @ 1.4 A
    DCR primary420 mOhm
    DCR secondary 116 mOhm
    DCR secondary 2not fitted
    DCR auxiliary115 mOhm
    Schematic variantWinding arrangement 2
    Package15.2 x 12.5 x 11.6 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1266

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1266; the package line above gives the body size where
    the data sheet states it.

    How to Read These Ratings

    A PoE PD flyback transformer takes the 37 to 57 V on the cable and steps it down to the rails the powered device needs, with the isolation barrier in between. The turns ratio, the primary inductance and the saturation current are set by the controller and the power level, not chosen freely.

    At the 0.45 A saturation point the primary stores about 25.6 uJ, which sets the maximum energy per switching cycle.

    Within the POEA1FB1V7W1X5 family this is item 1 of 1 in the Eaton catalogue.

    Where This Series Fits

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    Can I use a forward part in a flyback design?
    No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.

    What decides the turns ratio?
    The controller and the output rail. A flyback with a given primary inductance needs a specific ratio to keep the duty cycle in range at the minimum input voltage, so the ratio is set by the design, not chosen for convenience.

    Why is SCL quoted as well as OCL?
    OCL is the open-circuit inductance and SCL is the saturated value. The controller needs OCL to set the current ramp and SCL to know where the core runs out, and the gap between them is the usable current range.