Eaton POEA2FB1V10W2X5 Power over Ethernet Transformer
Eaton POEA2FB1V10W2X5 Power over Ethernet Transformer

Eaton POEA2FB1V10W2X5 Power over Ethernet Transformer

Share
POEA2FB1V10W2X5: PoE transformer, 1:0.167:0.167:0.36 turns ratio, 10 W.
    • Product Details
    • Download

    Eaton POEA2FB1V10W2X5 Power over Ethernet Transformer

    POEA2FB1V10W2X5 at a glance: PoE transformer, 1:0.167:0.167:0.36 turns ratio, 10 W.

    Key Specifications

    ParameterValue
    Orderable part numberPOEA2FB1V10W2X5
    Output power10 W
    OCL (primary inductance)180 uH
    SCL (saturated inductance)1.2 uH
    Isat1 A
    Turns ratio pri : sec : aux1:0.167:0.167:0.36
    Output configuration(2) x 5.0 V
    DCR primary330 mOhm
    DCR secondary 113.5 mOhm
    DCR secondary 2190 mOhm
    DCR auxiliary230 mOhm
    Schematic variantWinding arrangement 1
    Package14.2 x 17.75 x 12.7 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1267

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1267; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    The part carries the full PD power through a small EFD or EPC core, so the design squeeze is between saturation at the peak primary current and core loss at the switching frequency. The data sheet gives OCL, SCL and Isat so both can be checked.

    At the 1 A saturation point the primary stores about 90 uJ, which sets the maximum energy per switching cycle.

    Within the POEA2FB1V10W2X5 family this is item 1 of 1 in the Eaton catalogue.

    Where This Series Fits

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    Can I use a forward part in a flyback design?
    No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.

    What does the schematic number mean?
    It refers to the winding arrangement drawing in the data sheet: which winding is primary, how many secondaries, and where the auxiliary sits. Two parts with the same power level and different schematic numbers are not interchangeable.

    Is the isolation reinforced?
    The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.