| Parameter | Value |
|---|---|
| Orderable part number | POEA2FB1V10W2X5 |
| Output power | 10 W |
| OCL (primary inductance) | 180 uH |
| SCL (saturated inductance) | 1.2 uH |
| Isat | 1 A |
| Turns ratio pri : sec : aux | 1:0.167:0.167:0.36 |
| Output configuration | (2) x 5.0 V |
| DCR primary | 330 mOhm |
| DCR secondary 1 | 13.5 mOhm |
| DCR secondary 2 | 190 mOhm |
| DCR auxiliary | 230 mOhm |
| Schematic variant | Winding arrangement 1 |
| Package | 14.2 x 17.75 x 12.7 mm |
| Mounting | Surface mount |
| Operating temperature | -40 C to +125 C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1267 |
Outline drawing, winding arrangement and recommended pad layout are on
page 2 of Eaton Technical Data ELX1267; the package line above gives the body size where
the data sheet states it.
The part carries the full PD power through a small EFD or EPC core, so the design squeeze is between saturation at the peak primary current and core loss at the switching frequency. The data sheet gives OCL, SCL and Isat so both can be checked.
At the 1 A saturation point the primary stores about 90 uJ, which sets the maximum energy per switching cycle.
Within the POEA2FB1V10W2X5 family this is item 1 of 1 in the Eaton catalogue.
The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.
Can I use a forward part in a flyback design?
No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.
What does the schematic number mean?
It refers to the winding arrangement drawing in the data sheet: which winding is primary, how many secondaries, and where the auxiliary sits. Two parts with the same power level and different schematic numbers are not interchangeable.
Is the isolation reinforced?
The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd