Eaton POEA2FB1V18W1X12 PoE PD Transformer 18 W
Eaton POEA2FB1V18W1X12 PoE PD Transformer 18 W

Eaton POEA2FB1V18W1X12 PoE PD Transformer 18 W

Share
POEA2FB1V18W1X12: PoE transformer, 1:0.333:0.333 turns ratio, 18 W.
    • Product Details
    • Download

    Eaton POEA2FB1V18W1X12 PoE PD Transformer 18 W

    POEA2FB1V18W1X12 at a glance: PoE transformer, 1:0.333:0.333 turns ratio, 18 W.

    Key Specifications

    ParameterValue
    Orderable part numberPOEA2FB1V18W1X12
    Output power18 W
    OCL (primary inductance)37 uH
    SCL (saturated inductance)0.56 uH
    Isat2.7 A
    Turns ratio pri : sec : aux1:0.333:0.333
    Output configuration(1) x 12.0 V @ 1.5 A
    DCR primary70 mOhm
    DCR secondary 112 mOhm
    DCR secondary 2not fitted
    DCR auxiliary180 mOhm
    Package14.2 x 17.75 x 12.7 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1267

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1267; the package line above gives the body size where
    the data sheet states it.

    How to Read These Ratings

    A PoE PD flyback transformer takes the 37 to 57 V on the cable and steps it down to the rails the powered device needs, with the isolation barrier in between. The turns ratio, the primary inductance and the saturation current are set by the controller and the power level, not chosen freely.

    At the 2.7 A saturation point the primary stores about 135 uJ, which sets the maximum energy per switching cycle.

    Within the POEA2FB1V18W1X12 family this is item 1 of 1 in the Eaton catalogue.

    Series Positioning

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    Is the isolation reinforced?
    The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.

    What decides the turns ratio?
    The controller and the output rail. A flyback with a given primary inductance needs a specific ratio to keep the duty cycle in range at the minimum input voltage, so the ratio is set by the design, not chosen for convenience.

    What decides the turns ratio?
    The controller and the output rail. A flyback with a given primary inductance needs a specific ratio to keep the duty cycle in range at the minimum input voltage, so the ratio is set by the design, not chosen for convenience.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message