Eaton POEA2FB2V13W1X5 PoE PD Transformer 13 W
Eaton POEA2FB2V13W1X5 PoE PD Transformer 13 W

Eaton POEA2FB2V13W1X5 PoE PD Transformer 13 W

Share
POEA2FB2V13W1X5: PoE transformer, 1:0.25:0.5 turns ratio, 13 W.
    • Product Details
    • Download

    Eaton POEA2FB2V13W1X5 PoE PD Transformer 13 W

    POEA2FB2V13W1X5 at a glance: PoE transformer, 1:0.25:0.5 turns ratio, 13 W.

    Key Specifications

    ParameterValue
    Orderable part numberPOEA2FB2V13W1X5
    Output power13 W
    OCL (primary inductance)127 uH
    SCL (saturated inductance)0.95 uH
    Isat1.5 A
    Turns ratio pri : sec : aux1:0.25:0.5
    Output configuration(1) x 5.0 V @ 2.6 A
    DCR primary222 mOhm
    DCR secondary 139 mOhm
    DCR secondary 2not fitted
    DCR auxiliary348 mOhm
    Schematic variantWinding arrangement 6
    Package14.2 x 17.75 x 12.7 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1267

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1267; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    PoE transformers are wound for a specific controller family, which is why the schematic column matters: the same core and power level can be wound as 1:0.389 or 1:0.143 depending on the output rail.

    At the 1.5 A saturation point the primary stores about 143 uJ, which sets the maximum energy per switching cycle.

    Within the POEA2FB2V13W1X5 family this is item 1 of 1 in the Eaton catalogue.

    What This Family Is For

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    Can I use a forward part in a flyback design?
    No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.

    What decides the turns ratio?
    The controller and the output rail. A flyback with a given primary inductance needs a specific ratio to keep the duty cycle in range at the minimum input voltage, so the ratio is set by the design, not chosen for convenience.

    Can I use a forward part in a flyback design?
    No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.