Eaton POEA2FB2V14W1X5 Flyback Transformer 1:0.25:0.535
Eaton POEA2FB2V14W1X5 Flyback Transformer 1:0.25:0.535

Eaton POEA2FB2V14W1X5 Flyback Transformer 1:0.25:0.535

Share
POEA2FB2V14W1X5: PoE transformer, 1:0.25:0.535 turns ratio, 14 W.
    • Product Details
    • Download

    Eaton POEA2FB2V14W1X5 Flyback Transformer 1:0.25:0.535

    POEA2FB2V14W1X5 at a glance: PoE transformer, 1:0.25:0.535 turns ratio, 14 W.

    Key Specifications

    ParameterValue
    Orderable part numberPOEA2FB2V14W1X5
    Output power14 W
    OCL (primary inductance)100 uH
    SCL (saturated inductance)0.88 uH
    Isat1.4 A
    Turns ratio pri : sec : aux1:0.25:0.535
    Output configuration(1) x 5.0 V @ 2.8 A
    DCR primary210 mOhm
    DCR secondary 19 mOhm
    DCR secondary 2not fitted
    DCR auxiliary300 mOhm
    Package14.2 x 17.75 x 12.7 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1267

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1267; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    This is a flyback transformer for Power over Ethernet powered devices: primary, secondary and an auxiliary winding for the controller supply, all on one bobbin with reinforced insulation between primary and secondary.

    At the 1.4 A saturation point the primary stores about 98 uJ, which sets the maximum energy per switching cycle.

    Within the POEA2FB2V14W1X5 family this is item 1 of 1 in the Eaton catalogue.

    Positioning in the Range

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    What does the schematic number mean?
    It refers to the winding arrangement drawing in the data sheet: which winding is primary, how many secondaries, and where the auxiliary sits. Two parts with the same power level and different schematic numbers are not interchangeable.

    What decides the turns ratio?
    The controller and the output rail. A flyback with a given primary inductance needs a specific ratio to keep the duty cycle in range at the minimum input voltage, so the ratio is set by the design, not chosen for convenience.

    Can I use a forward part in a flyback design?
    No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.