POEB1FB1V18W1X12: PoE transformer, 1:0.343:0.314 turns ratio, 18 W.
    • Product Details
    • Download

    Eaton POEB1FB1V18W1X12 PoE Flyback Transformer, 18 W

    POEB1FB1V18W1X12 at a glance: PoE transformer, 1:0.343:0.314 turns ratio, 18 W.

    Specification Table

    ParameterValue
    Orderable part numberPOEB1FB1V18W1X12
    Output power18 W
    OCL (primary inductance)70 uH
    SCL (saturated inductance)1.8 uH
    Isat2 A
    Turns ratio pri : sec : aux1:0.343:0.314
    Output configuration(1) x 12.0 V @ 1.5 A
    DCR primary260 mOhm
    DCR secondary 130 mOhm
    DCR secondary 2not fitted
    DCR auxiliary270 mOhm
    Schematic variantWinding arrangement 4
    Package22.3 x 17.3 x 9 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1268

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1268; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    The part carries the full PD power through a small EFD or EPC core, so the design squeeze is between saturation at the peak primary current and core loss at the switching frequency. The data sheet gives OCL, SCL and Isat so both can be checked.

    At the 2 A saturation point the primary stores about 140 uJ, which sets the maximum energy per switching cycle.

    Within the POEB1FB1V18W1X12 family this is item 1 of 1 in the Eaton catalogue.

    Positioning in the Range

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    Why is SCL quoted as well as OCL?
    OCL is the open-circuit inductance and SCL is the saturated value. The controller needs OCL to set the current ramp and SCL to know where the core runs out, and the gap between them is the usable current range.

    Is the isolation reinforced?
    The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.

    What does the schematic number mean?
    It refers to the winding arrangement drawing in the data sheet: which winding is primary, how many secondaries, and where the auxiliary sits. Two parts with the same power level and different schematic numbers are not interchangeable.