Eaton POEB2FB1V24W2X12 PoE PD Transformer 24 W
Eaton POEB2FB1V24W2X12 PoE PD Transformer 24 W

Eaton POEB2FB1V24W2X12 PoE PD Transformer 24 W

Share
POEB2FB1V24W2X12: PoE transformer, 1:1:0.9:0.9 turns ratio, 24 W.
    • Product Details
    • Download

    Eaton POEB2FB1V24W2X12 PoE PD Transformer 24 W

    POEB2FB1V24W2X12 at a glance: PoE transformer, 1:1:0.9:0.9 turns ratio, 24 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberPOEB2FB1V24W2X12
    Output power24 W
    OCL (primary inductance)11.5 uH
    SCL (saturated inductance)0.5 uH
    Isat3 A
    Turns ratio pri : sec : aux1:1:0.9:0.9
    Output configuration(2) x 12.0 V
    DCR primary28 mOhm
    DCR secondary 123 mOhm
    DCR secondary 2130 mOhm
    DCR auxiliary130 mOhm
    Schematic variantWinding arrangement 1
    Package29.3 x 21.8 x 12 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1269

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1269; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    This is a flyback transformer for Power over Ethernet powered devices: primary, secondary and an auxiliary winding for the controller supply, all on one bobbin with reinforced insulation between primary and secondary.

    At the 3 A saturation point the primary stores about 51.8 uJ, which sets the maximum energy per switching cycle.

    Within the POEB2FB1V24W2X12 family this is item 1 of 1 in the Eaton catalogue.

    Where This Series Fits

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    What does the schematic number mean?
    It refers to the winding arrangement drawing in the data sheet: which winding is primary, how many secondaries, and where the auxiliary sits. Two parts with the same power level and different schematic numbers are not interchangeable.

    Is the isolation reinforced?
    The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.

    Why is SCL quoted as well as OCL?
    OCL is the open-circuit inductance and SCL is the saturated value. The controller needs OCL to set the current ramp and SCL to know where the core runs out, and the gap between them is the usable current range.