Eaton POEB3FB1V48W1X12 Flyback Transformer 1:1.07:1.07
Eaton POEB3FB1V48W1X12 Flyback Transformer 1:1.07:1.07

Eaton POEB3FB1V48W1X12 Flyback Transformer 1:1.07:1.07

Share
POEB3FB1V48W1X12: PoE transformer, 1:1.07:1.07 turns ratio, 48 W.
    • Product Details
    • Download

    Eaton POEB3FB1V48W1X12 Flyback Transformer 1:1.07:1.07

    POEB3FB1V48W1X12 at a glance: PoE transformer, 1:1.07:1.07 turns ratio, 48 W.

    Specification Table

    ParameterValue
    Orderable part numberPOEB3FB1V48W1X12
    Output power48 W
    OCL (primary inductance)30 uH
    SCL (saturated inductance)1 uH
    Isat5 A
    Turns ratio pri : sec : aux1:1.07:1.07
    Output configuration(1) x 12.0 V @ 4.0 A
    DCR primary30 mOhm
    DCR secondary 150 mOhm
    DCR secondary 2not fitted
    DCR auxiliary500 mOhm
    Schematic variantWinding arrangement 1
    Package32.8 x 26.8 x 14.8 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1270

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1270; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    PoE transformers are wound for a specific controller family, which is why the schematic column matters: the same core and power level can be wound as 1:0.389 or 1:0.143 depending on the output rail.

    At the 5 A saturation point the primary stores about 375 uJ, which sets the maximum energy per switching cycle.

    Within the POEB3FB1V48W1X12 family this is item 1 of 1 in the Eaton catalogue.

    Series Positioning

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    Can I use a forward part in a flyback design?
    No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.

    What does the schematic number mean?
    It refers to the winding arrangement drawing in the data sheet: which winding is primary, how many secondaries, and where the auxiliary sits. Two parts with the same power level and different schematic numbers are not interchangeable.

    Why is SCL quoted as well as OCL?
    OCL is the open-circuit inductance and SCL is the saturated value. The controller needs OCL to set the current ramp and SCL to know where the core runs out, and the gap between them is the usable current range.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message