| Parameter | Value |
|---|---|
| Orderable part number | POEB3FB1V84W2X12 |
| Output power | 84 W |
| OCL (primary inductance) | 17.5 uH |
| SCL (saturated inductance) | 1 uH |
| Isat | 22 A |
| Turns ratio pri : sec : aux | 1:0.273:0.273:0.227 |
| Output configuration | (2) x 12.0 V |
| DCR primary | 85 mOhm |
| DCR secondary 1 | 7 mOhm |
| DCR secondary 2 | 35 mOhm |
| DCR auxiliary | 100 mOhm |
| Schematic variant | Winding arrangement 2 |
| Package | 32.8 x 26.8 x 14.8 mm |
| Mounting | Surface mount |
| Operating temperature | -40 C to +125 C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1270 |
Outline drawing, winding arrangement and recommended pad layout are on
page 2 of Eaton Technical Data ELX1270; the package line above gives the body size where
the data sheet states it.
PoE transformers are wound for a specific controller family, which is why the schematic column matters: the same core and power level can be wound as 1:0.389 or 1:0.143 depending on the output rail.
At the 22 A saturation point the primary stores about 4235 uJ, which sets the maximum energy per switching cycle.
Within the POEB3FB1V84W2X12 family this is item 1 of 1 in the Eaton catalogue.
The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.
What decides the turns ratio?
The controller and the output rail. A flyback with a given primary inductance needs a specific ratio to keep the duty cycle in range at the minimum input voltage, so the ratio is set by the design, not chosen for convenience.
Is the isolation reinforced?
The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.
What decides the turns ratio?
The controller and the output rail. A flyback with a given primary inductance needs a specific ratio to keep the duty cycle in range at the minimum input voltage, so the ratio is set by the design, not chosen for convenience.
Shenzhen Gaorunxin Technology Co., Ltd