Eaton POEB3FW1V50W1X5 PoE Flyback Transformer, 50 W
Eaton POEB3FW1V50W1X5 PoE Flyback Transformer, 50 W

Eaton POEB3FW1V50W1X5 PoE Flyback Transformer, 50 W

Share
POEB3FW1V50W1X5: PoE transformer, 1:0.222:0.556 turns ratio, 50 W.
    • Product Details
    • Download

    Eaton POEB3FW1V50W1X5 PoE Flyback Transformer, 50 W

    POEB3FW1V50W1X5 at a glance: PoE transformer, 1:0.222:0.556 turns ratio, 50 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberPOEB3FW1V50W1X5
    Output power50 W
    OCL (primary inductance)162 uH
    Isat0.3 A
    Turns ratio pri : sec : aux1:0.222:0.556
    Output configuration(1) x 5.0 V @ 10.0 A
    DCR primary30 mOhm
    DCR secondary 15 mOhm
    DCR secondary 260 mOhm
    DCR auxiliary1 mOhm
    Package32.8 x 26.8 x 14.8 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1271

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1271; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    This is a flyback transformer for Power over Ethernet powered devices: primary, secondary and an auxiliary winding for the controller supply, all on one bobbin with reinforced insulation between primary and secondary.

    At the 0.3 A saturation point the primary stores about 7.29 uJ, which sets the maximum energy per switching cycle.

    Within the POEB3FW1V50W1X5 family this is item 1 of 1 in the Eaton catalogue.

    What This Family Is For

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    What decides the turns ratio?
    The controller and the output rail. A flyback with a given primary inductance needs a specific ratio to keep the duty cycle in range at the minimum input voltage, so the ratio is set by the design, not chosen for convenience.

    Why is SCL quoted as well as OCL?
    OCL is the open-circuit inductance and SCL is the saturated value. The controller needs OCL to set the current ramp and SCL to know where the core runs out, and the gap between them is the usable current range.

    Can I use a forward part in a flyback design?
    No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.