| Parameter | Value |
|---|---|
| Orderable part number | RL0607-100-R |
| Inductance | 10 uH |
| DCR typical @ +20 °C | 21000 mOhm |
| Irms (DC, 40 °C rise) | 1.51 A |
| Isat | 0.058 A |
| Mounting | Through-hole |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10334 |

Drawing reproduced from Eaton Technical Data 10334: outline with
rated mm dimensions, pad layout and marking.
A radial leaded drum core inductor with a protective sleeve over the winding. The leads drop into plated holes, so the part is mechanically anchored to the board rather than held by a solder fillet alone.
At 1.51 A the winding dissipates about 47.9 W in copper using the typical DCR of 21000 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.
The core stores about 0.017 uJ at the saturation point, which is the energy available to bridge a load step.
Within the RL0607 family this is value 2 of 12, in a range from 6.8 uH to 1500 uH.
The RL family is the radial leaded drum core range: through-hole parts with a protective sleeve, covering microhenry to millihenry values.
Why a sleeve over the winding?
It protects the coil during handling and gives the part a defined outside diameter for automated placement.
What current can the leads carry?
The Irms column is the thermal rating for the part; the lead and the plated hole also have to be checked at that current.
Is the part shielded?
No. The drum is open at the ends, so keep sensitive traces away from the axis.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd