| Parameter | Value |
|---|---|
| Orderable part number | RL0809-123-R |
| Inductance | 12011 uH |
| DCR typical @ +20 °C | 30000 mOhm |
| Irms (DC, 40 °C rise) | 0.093 A |
| Isat | 0.07 A |
| SRF typical | 0.52 MHz |
| Mounting | Through-hole |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10279 |

Drawing reproduced from Eaton Technical Data 10279: outline with
rated mm dimensions, pad layout and marking.
This is a through-hole drum core choke: ferrite drum, wound coil, heat-shrink sleeve, tinned leads. The value range runs from a few microhenry into the millihenry region.
At 0.093 A the winding dissipates about 0.259 W in copper using the typical DCR of 30000 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.
The core stores about 29.4 uJ at the saturation point, which is the energy available to bridge a load step.
Self-resonance is 0.52 MHz typical. Keep the operating band, and the harmonics that carry energy, below it.
Within the RL0809 family this is value 10 of 12, in a range from 9.65 uH to 32998 uH.
The RL family is the radial leaded drum core range: through-hole parts with a protective sleeve, covering microhenry to millihenry values.
Why a sleeve over the winding?
It protects the coil during handling and gives the part a defined outside diameter for automated placement.
What current can the leads carry?
The Irms column is the thermal rating for the part; the lead and the plated hole also have to be checked at that current.
Can it be used in a switching supply?
Yes, at the switching frequencies its core loss allows. Compare the core loss curve before assuming the DC rating is the limit.
Shenzhen Gaorunxin Technology Co., Ltd