| Parameter | Value |
|---|---|
| Orderable part number | SD3118-102-R |
| Inductance | 999 uH ±20% |
| DCR typical @ +20 °C | 21000 mOhm |
| Irms (DC, 40 °C rise) | 0.087 A |
| Isat | 0.083 A |
| K-factor | 3 |
| Package | 31 x 18 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4084 |

Drawing reproduced from Eaton Technical Data 4084: outline with
rated mm dimensions, pad layout and marking.
The drum core concentrates the flux and the shield closes the return path, so this family behaves more like a closed-core part than an open drum while keeping the inductance-per-volume advantage of a wound component.
At 0.087 A the winding dissipates about 0.159 W in copper using the typical DCR of 21000 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.
The core stores about 3.44 uJ at the saturation point, which is the energy available to bridge a load step.
The K-factor of 3 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.
Within the SD3118 family this is value 15 of 15, in a range from 1.04 uH to 999 uH.
The SD family is the shielded drum core range: SMD parts from about 3 mm to 8 mm, covering sub-microhenry to hundreds of microhenry at currents from a few hundred milliamps to several amps.
Is the part suitable for a switching converter?
Yes within its current and frequency range. Check the core loss at the switching frequency before assuming the DC rating is the limit.
What does the shield actually do?
It closes the magnetic return path around the drum, which reduces the fringing field that would otherwise couple into nearby traces.
What is the Volt-us column?
The applied volt-time product that produces a defined core loss. It is the figure to compare against the converter waveform at the switching frequency.
Shenzhen Gaorunxin Technology Co., Ltd