Eaton SD6020-220-R 20 uH SMD Power Inductor
Eaton SD6020-220-R 20 uH SMD Power Inductor

Eaton SD6020-220-R 20 uH SMD Power Inductor

Share
SD6020-220-R: shielded drum core inductor, 20 uH , 0.94 A Irms, Isat 0.8 A, DCR 241700 mOhm.
    • Product Details
    • Download

    Eaton SD6020-220-R 20 uH SMD Power Inductor

    SD6020-220-R at a glance: shielded drum core inductor, 20 uH , 0.94 A Irms, Isat 0.8 A, DCR 241700 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSD6020-220-R
    Inductance20 uH
    DCR typical @ +20 °C241700 mOhm
    DCR maximum @ +20 °C290000 mOhm
    Irms (DC, 40 °C rise)0.94 A
    Isat0.8 A
    K-factor12.7
    Package6 x 6 x 2 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4144

    Dimensions and Pad Layout

    SD6020-220-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4144: outline with
    rated mm dimensions, pad layout and marking.

    The Figures Explained

    Shielded drum cores are chosen when the board is dense and the inductor cannot be allowed to radiate. The data sheet gives Irms for the thermal limit and Isat for the inductance rolloff – two different constraints on the same part.

    At 0.94 A the winding dissipates about 214 W in copper using the typical DCR of 241700 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 6.4 uJ at the saturation point, which is the energy available to bridge a load step.

    The K-factor of 12.7 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.

    Within the SD6020 family this is value 10 of 18, in a range from 1.99 uH to 94 uH.

    Series Positioning

    The SD family is the shielded drum core range: SMD parts from about 3 mm to 8 mm, covering sub-microhenry to hundreds of microhenry at currents from a few hundred milliamps to several amps.

    • The shield reduces but does not eliminate the external field. Check the layout against the EMC plan before placing sensitive traces close.
    • Typical applications: notebook, laptop computers; digital cameras; led drivers; tft lcd bias supplies; wireless handsets,.
    • Design note: on a shielded drum the Isat and Irms limits can differ a lot. Size against whichever is lower for the application.

    Frequently Asked Questions

    What is the Volt-us column?
    The applied volt-time product that produces a defined core loss. It is the figure to compare against the converter waveform at the switching frequency.

    Why is Isat lower than Irms on some rows?
    They are different limits: Irms is thermal, Isat is magnetic. On a high-inductance part the core saturates before the winding overheats.

    Why is Isat lower than Irms on some rows?
    They are different limits: Irms is thermal, Isat is magnetic. On a high-inductance part the core saturates before the winding overheats.