Eaton SDCHA1V6045-5R6-R 5.6 uH Automotive Inductor 31 mOhm
Eaton SDCHA1V6045-5R6-R 5.6 uH Automotive Inductor 31 mOhm

Eaton SDCHA1V6045-5R6-R 5.6 uH Automotive Inductor 31 mOhm

Share
SDCHA1V6045-5R6-R: AEC-Q200 semi-shielded inductor, 5.6 uH ±20%, 4.1 A Irms, Isat 6.4 A, DCR 31 mOhm.
    • Product Details
    • Download

    Eaton SDCHA1V6045-5R6-R 5.6 uH Automotive Inductor 31 mOhm

    SDCHA1V6045-5R6-R at a glance: AEC-Q200 semi-shielded inductor, 5.6 uH ±20%, 4.1 A Irms, Isat 6.4 A, DCR 31 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberSDCHA1V6045-5R6-R
    Inductance5.6 uH ±20%
    FLL minimum (at Isat)3.14 uH
    DCR typical @ +20 °C31 mOhm
    Irms (DC, 40 °C rise)4.1 A
    Isat6.4 A
    SRF typical35 MHz
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1096

    Dimensions and Pad Layout

    SDCHA1V6045-5R6-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1096: outline with
    rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    The automotive version of the semi-shielded power inductor: AEC-Q200 qualified, characterised over the full temperature range, and built with a magnetic resin shield that keeps radiated emissions low in a dense module.

    At 4.1 A the winding dissipates about 0.521 W in copper using the typical DCR of 31 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 115 uJ at the saturation point, which is the energy available to bridge a load step.

    Self-resonance is 35 MHz typical. Keep the operating band, and the harmonics that carry energy, below it.

    Within the SDCHA1V6045 family this is value 9 of 20, in a range from 1 uH to 100 uH.

    What This Family Is For

    The SDCA family is the automotive semi-shielded range: the same construction as the commercial parts, qualified to AEC-Q200 and characterised across the temperature range.

    • Qualification covers the part, not the module. The thermal design of the board is still the engineer’s job.
    • Typical applications: led lighting; advanced driver assistance systems (adas); adaptive cruise control (acc); collision avoidance; infotainment and cluster electronics.
    • Design note: use the maximum DCR at the hot corner for the loss budget, and Isat at the same temperature for the transient.

    Frequently Asked Questions

    What does AEC-Q200 cover?
    The passive-component qualification regime: thermal shock, cycling, vibration, moisture and solderability. It qualifies the construction, not the board design.

    Is the part fully shielded?
    It is semi-shielded: a magnetic resin over the winding. That is adequate for most module layouts but is not a closed metal shield.

    How do I check the hot corner?
    Use Isat at the highest operating temperature and the maximum DCR at that temperature. The room-temperature row is the optimistic one.

    Shenzhen Gaorunxin Technology Co., Ltd