| Parameter | Value |
|---|---|
| Orderable part number | SDCL1V2010-1R0N-R |
| Inductance | 1 uH ±30% |
| FLL minimum (at Isat) | 0.46 uH |
| DCR typical @ +20 °C | 95 mOhm |
| DCR maximum @ +20 °C | 110 mOhm |
| Irms (DC, 40 °C rise) | 1.55 A |
| Isat | 1.8 A |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1029 |

Drawing reproduced from Eaton Technical Data ELX1029: outline with
rated mm dimensions, pad layout and marking.
Semi-shielded construction is a compromise that works: enough magnetic material around the coil to keep radiated emissions low, but an open enough structure to keep the DCR and the cost down. Common on consumer and industrial DC-DC rails.
At 1.55 A the winding dissipates about 0.228 W in copper using the typical DCR of 95 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.
The core stores about 1.62 uJ at the saturation point, which is the energy available to bridge a load step.
Within the SDCL1V2010 family this is value 3 of 10, in a range from 0.47 uH to 15 uH.
The SDC family is the semi-shielded range: low-profile SMD inductors from about 2 mm to 6 mm, aimed at compact DC-DC converters where a full shield is not needed.
Is the inductance stable with temperature?
The tolerance is quoted over the operating range; the drift inside that band is small for a wound ferrite part.
How much shielding does semi-shielded give?
Enough to damp the fringing field substantially, but less than a closed metal shield. For EMC-critical layouts check the radiated field against the test plan.
Is the inductance stable with temperature?
The tolerance is quoted over the operating range; the drift inside that band is small for a wound ferrite part.