| Parameter | Value |
|---|---|
| Orderable part number | SDCL1V4018-330M-R |
| Inductance | 33 uH ±20% |
| FLL minimum (at Isat) | 17.2 uH |
| DCR typical @ +20 °C | 550 mOhm |
| DCR maximum @ +20 °C | 633 mOhm |
| Irms (DC, 40 °C rise) | 0.7 A |
| Isat | 0.73 A |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1032 |

Drawing reproduced from Eaton Technical Data ELX1032: outline with
rated mm dimensions, pad layout and marking.
The part is a wound coil with a magnetic coating: cheaper than a fully shielded part, quieter than an open drum. Check the Isat column for the transient and the Irms column for the thermal limit.
At 0.7 A the winding dissipates about 0.269 W in copper using the typical DCR of 550 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.
The core stores about 8.79 uJ at the saturation point, which is the energy available to bridge a load step.
Within the SDCL1V4018 family this is value 10 of 14, in a range from 1 uH to 220 uH.
The SDC family is the semi-shielded range: low-profile SMD inductors from about 2 mm to 6 mm, aimed at compact DC-DC converters where a full shield is not needed.
Is the inductance stable with temperature?
The tolerance is quoted over the operating range; the drift inside that band is small for a wound ferrite part.
How much shielding does semi-shielded give?
Enough to damp the fringing field substantially, but less than a closed metal shield. For EMC-critical layouts check the radiated field against the test plan.
Why quote both Irms and Isat?
Because they describe different failure modes: overheating and saturation. A design has to satisfy both.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd