Eaton SDCLA1V4018-100-R 10 uH AEC-Q200 Inductor, 1.2 A
Eaton SDCLA1V4018-100-R 10 uH AEC-Q200 Inductor, 1.2 A

Eaton SDCLA1V4018-100-R 10 uH AEC-Q200 Inductor, 1.2 A

Share
SDCLA1V4018-100-R: AEC-Q200 semi-shielded inductor, 10 uH ±20%, 1.2 A Irms, Isat 1.3 A, DCR 150 mOhm.
    • Product Details
    • Download

    Eaton SDCLA1V4018-100-R 10 uH AEC-Q200 Inductor, 1.2 A

    SDCLA1V4018-100-R at a glance: AEC-Q200 semi-shielded inductor, 10 uH ±20%, 1.2 A Irms, Isat 1.3 A, DCR 150 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberSDCLA1V4018-100-R
    Inductance10 uH ±20%
    FLL minimum (at Isat)5.6 uH
    DCR typical @ +20 °C150 mOhm
    Irms (DC, 40 °C rise)1.2 A
    Isat1.3 A
    SRF typical25 MHz
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1098

    Dimensions and Pad Layout

    SDCLA1V4018-100-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1098: outline with
    rated mm dimensions, pad layout and marking.

    Reading the Data Sheet

    This part is used on body electronics and ADAS power rails where the inductor has to be qualified, shielded enough for EMC, and small enough to fit beside the regulator.

    At 1.2 A the winding dissipates about 0.216 W in copper using the typical DCR of 150 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 8.45 uJ at the saturation point, which is the energy available to bridge a load step.

    Self-resonance is 25 MHz typical. Keep the operating band, and the harmonics that carry energy, below it.

    Within the SDCLA1V4018 family this is value 7 of 9, in a range from 1 uH to 22 uH.

    Where This Series Fits

    The SDCA family is the automotive semi-shielded range: the same construction as the commercial parts, qualified to AEC-Q200 and characterised across the temperature range.

    • Qualification covers the part, not the module. The thermal design of the board is still the engineer’s job.
    • Typical applications: led lighting; advanced driver assistance systems (adas); adaptive cruise control (acc); collision avoidance; infotainment and cluster electronics.
    • Design note: use the maximum DCR at the hot corner for the loss budget, and Isat at the same temperature for the transient.

    Frequently Asked Questions

    Is the part fully shielded?
    It is semi-shielded: a magnetic resin over the winding. That is adequate for most module layouts but is not a closed metal shield.

    What does AEC-Q200 cover?
    The passive-component qualification regime: thermal shock, cycling, vibration, moisture and solderability. It qualifies the construction, not the board design.

    How do I check the hot corner?
    Use Isat at the highest operating temperature and the maximum DCR at that temperature. The room-temperature row is the optimistic one.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message