    Key Specifications

    ParameterValue
    Orderable part numberSDQ25-470-R
    Rated inductance47 uH
    OCL, parallel47.4 uH
    Irms, parallel0.749 A
    Isat, parallel0.584 A
    DCR, parallel typical446 mOhm
    Volt-time, parallel25.4 V-us
    OCL, series190 uH
    Irms, series0.374 A
    Isat, series0.292 A
    DCR, series typical1.78 Ohm
    Volt-time, series50.8 V-us
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4339

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data 4339; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    This is the low-profile shielded version of the dual winding drum: the two windings are brought out to separate pads so they can be paralleled, series-connected or used as a 1:1 transformer.

    Within the SDQ25 family this is item 14 of 24 in the Eaton catalogue.

    Positioning in the Range

    The SDQ range covers 0.47 uH to 1000 uH in parallel, low profile, shielded, with both windings on one drum.

    • Paralleling the windings halves the inductance. Confirm the connection before calculating ripple.
    • Typical applications: transformer: (1:1), sepic, flyback; buck, boost, coupled inductor; mobile phones; notebook and laptop power; digital cameras.
    • Design note: the marking letter is the inductance bin. Keep it visible on the assembly drawing.

    Frequently Asked Questions

    Why two windings on one core?
    So one part can be a high-current low-inductance choke or a lower-current higher-inductance one, and so the coupling can be used deliberately in interleaved converters.

    What is the marking letter for?
    It identifies the inductance bin on the body, so a placed part can be checked against the bill of materials without measuring it.

    How much coupling is there?
    The windings share the drum, so coupling is tight – close to 1 for the intended configurations. That is why parallel connection halves the inductance instead of leaving it unchanged.