Eaton SS-5-1.6A-AP 1.6 A 250 Vac Time-Delay Subminiature Fuse
Eaton SS-5-1.6A-AP 1.6 A 250 Vac Time-Delay Subminiature Fuse

Eaton SS-5-1.6A-AP 1.6 A 250 Vac Time-Delay Subminiature Fuse

Share
Eaton SS-5-1.6A-AP is a 1.6 A 250 Vac time-delay subminiature radial fuse, 35 A breaking, 23 A2s I2t.
    • Product Details
    • Download

    Eaton SS-5-1.6A-AP 1.6 A 250 Vac Time-Delay Subminiature Fuse

    SS-5-1.6A-AP at a glance: 1.6 A, 250 Vac, 35 A breaking, 23 A2s I2t, 41 mOhm cold - radial leaded, time-delay, rectangular in a UL 94V0 body.

    Core Specifications

    ParameterValue
    Orderable part numberSS-5-1.6A-AP (-AP = 1,000 pcs ammo pack, 12.7 mm pitch)
    DC cold resistance, typical41 mOhm
    Interrupting rating35 A at rated voltage, 50 Hz
    Typical melting I2t23 A2s
    CharacteristicTime-delay (T)
    Dissipation at rating0.11 W
    AgencyUL E19180 (JDYX2/JDYX8) / VDE 40015513 / CCC / KC / SEMKO / PSE+JET
    Current rating1.6 A
    Design standardIEC 60127-3 sheet 4
    BodyRadial leaded, time-delay, rectangular, plastic cap and base, UL 94V0
    Typical voltage drop71.5 mV at rated current
    Voltage rating250 Vac

    At 1.6 A

    • Thermal reality. 0.11 W at 1.6 A, against 0.10 W from the cold resistance - the gap is the element temperature coefficient, and a plastic body traps it.
    • Melting integral. 23 A2s is the number to compare against a surge. A 2 x 1.6 A, 5 ms pulse uses 0.22 %.
    • Characteristic. Time-delay: it rides through a transformer or motor start, then still protects the winding.
    • Assembly. Thru-hole radial, wave or hand solder, UL 94V0 body. Ammonia-pack at 12.7 mm pitch for automatic insertion.
    • 0.5 A to 2 A band. 1.6 A is the volume centre of this series - adapters, set-top boxes and small appliances. The 23 A2s integral is large enough to ride a normal inrush and still small enough to protect a winding.
    • Neighbours. One step down is SS-5-1.25A-AP at 1.25 A, one step up is SS-5-2A-AP at 2 A. I2t goes 12.8 to 29.8 A2s across that range, so the choice is an inrush-margin decision rather than a resolution one.

    Ordering Notes

    • Part to order: SS-5-1.6A-AP. If your line needs a different reel, the suffix changes (-AP / -BK / -BK2) but the fuse does not.
    • Agency set: UL E19180 (JDYX2/JDYX8) / VDE 40015513 / CCC / KC / SEMKO / PSE+JET.
    • Designed to IEC 60127-3 sheet 4.
    • Do not substitute the fast-acting series where this time-delay part is specified - the inrush will open it.

    FAQ

    Is the whole part number required?
    Yes. Eaton's ordering code includes the packaging suffix - the bare rating is not a complete order line.

    What is the breaking capacity?
    35 A at rated voltage. That is low-breaking-capacity, appropriate for equipment-level protection, not a distribution board.

    How hot does it run?
    About 0.11 W at rated current, from 71.5 mV drop. In a sealed enclosure the derating curve applies.

    Design note: values are typical unless identified as ratings. Verify the current Eaton data sheet 2621 before release.