STS142050UL08: 5 V standoff TVS diode array, 2-channel, 0.8 pF per line, SOT-143 (S14), commercial grade.
    • Product Details
    • Download

    Eaton STS142050UL08 ESD Suppressor 5 V 0.8 pF

    STS142050UL08 at a glance: TVS diode array ESD suppressor, 5 V standoff, 20 V clamp, 2 channels, 0.8 pF, 60 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSTS142050UL08
    Standoff voltage (VRWM)5 V
    Breakdown voltage (min / typ / max)6 V / 7.2 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line60 W
    Forward clamping voltage at 1 A10.5 V
    Forward clamping voltage at 4.5 A15 V
    Clamping voltage at 8 A15 V
    Clamping voltage at 17 A20 V
    Junction capacitance at 1 MHz, per line0.8 pF typ / 1 pF max
    Channels2
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-20 kV contact / +/-30 kV air
    PackageSOT-143 (S14)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11146

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11146. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    The Figures Explained

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    At 17 A the clamp sits at 20 V, or 4.00 times the 5 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 60 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    0.8 pF per line is 199 ohms of reactance at 1 GHz and 1,989 ohms at 100 MHz. Low enough that the loading can be ignored on a high speed pair, which is what this capacitance grade is sold for.

    Standing at 5 V the part draws at most 1 uA, which is 5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    All 2 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    Placement in the Circuit

    Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.

    • A unidirectional array clamps one polarity at the breakdown and the other at a forward drop. That asymmetry is correct on a DC rail and wrong on a differential pair that swings below ground.
    • Breakdown is specified at 1 mA. The spread between minimum and maximum is production tolerance, so the design margin is measured from the minimum, not the typical.

    Frequently Asked Questions

    Why does the package affect the rating?
    It sets the thermal mass and the lead inductance. The same die in a SOD-523 and a SOT-23 dissipates differently, so the package is part of the electrical choice rather than only a footprint decision.

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.