Eaton STS232033B102 ESD Suppressor 3.3 V 100 pF
Eaton STS232033B102 ESD Suppressor 3.3 V 100 pF

Eaton STS232033B102 ESD Suppressor 3.3 V 100 pF

Share
STS232033B102: 3.3 V standoff TVS diode array, 2-channel, 100 pF per line, SOT-23 (S23), commercial grade.
    • Product Details
    • Download

    Eaton STS232033B102 ESD Suppressor 3.3 V 100 pF

    STS232033B102 at a glance: TVS diode array ESD suppressor, 3.3 V standoff, 8 V clamp, 2 channels, 100 pF, 350 W.

    Specification Table

    ParameterValue
    Orderable part numberSTS232033B102
    Standoff voltage (VRWM)3.3 V
    Breakdown voltage (min / typ / max)3.6 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line350 W
    Clamping voltage at 1 A8 V
    Junction capacitance at 1 MHz, per line100 pF typ
    Channels2
    PolarityBidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOT-23 (S23)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11147

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11147. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    How to Read These Ratings

    Eaton builds these on a silicon avalanche process, so the clamp is sharp and the part recovers without the off-state drift a metal oxide varistor shows after a surge. The trade is a fixed breakdown window that the working voltage has to sit below with margin.

    At 1 A the clamp sits at 8 V, or 2.42 times the 3.3 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    100 pF per line is 1.6 ohms of reactance at 1 GHz and 15.9 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 3.3 V the part draws at most 1 uA, which is 3.3 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    All 2 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.

    Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.

    Board Layout

    Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.

    • A unidirectional array clamps one polarity at the breakdown and the other at a forward drop. That asymmetry is correct on a DC rail and wrong on a differential pair that swings below ground.
    • Breakdown is specified at 1 mA. The spread between minimum and maximum is production tolerance, so the design margin is measured from the minimum, not the typical.

    Frequently Asked Questions

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.