| Parameter | Value |
|---|---|
| Orderable part number | STS232033B102 |
| Standoff voltage (VRWM) | 3.3 V |
| Breakdown voltage (min / typ / max) | 3.6 V |
| Leakage current at VRWM | 1 uA max |
| Peak pulse power, 8/20 us, per line | 350 W |
| Clamping voltage at 1 A | 8 V |
| Junction capacitance at 1 MHz, per line | 100 pF typ |
| Channels | 2 |
| Polarity | Bidirectional |
| ESD capability, IEC 61000-4-2 | +/-30 kV contact / +/-30 kV air |
| Package | SOT-23 (S23) |
| Mounting | Surface mount |
| Moisture sensitivity level | MSL 3 |
| Operating junction temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11147 |
The outline drawing, pad geometry, derating curves and the pulse
waveform are on the pages of Eaton Technical Data 11147. Values above are
read directly from the electrical table for this part number, not from the family
summary.
Eaton builds these on a silicon avalanche process, so the clamp is sharp and the part recovers without the off-state drift a metal oxide varistor shows after a surge. The trade is a fixed breakdown window that the working voltage has to sit below with margin.
At 1 A the clamp sits at 8 V, or 2.42 times the 3.3 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.
100 pF per line is 1.6 ohms of reactance at 1 GHz and 15.9 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.
Standing at 3.3 V the part draws at most 1 uA, which is 3.3 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.
All 2 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.
Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.
Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.
Why does the clamp voltage differ from the breakdown voltage?
Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.
What happens if the surge exceeds the rating?
The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.
How is the working voltage chosen?
Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd