Eaton STS232050U152AH ESD Suppressor 5 V 150 pF
Eaton STS232050U152AH ESD Suppressor 5 V 150 pF

Eaton STS232050U152AH ESD Suppressor 5 V 150 pF

Share
STS232050U152AH: 5 V standoff TVS diode array, 2-channel, 150 pF per line, SOT-23 (S23), AEC-Q101.
    • Product Details
    • Download

    Eaton STS232050U152AH ESD Suppressor 5 V 150 pF

    STS232050U152AH at a glance: TVS diode array ESD suppressor, 5 V standoff, 16.7 V clamp, 2 channels, 150 pF, 350 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSTS232050U152AH
    Standoff voltage (VRWM)5 V
    Breakdown voltage (min / typ / max)6 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line350 W
    Clamping voltage at 1 A9.8 V
    Clamping voltage at 18 A16.7 V
    Junction capacitance at 1 MHz, per line150 pF typ / 180 pF max
    Channels2
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOT-23 (S23)
    MountingSurface mount
    Moisture sensitivity levelMSL 1
    Operating junction temperature-55 °C to +150 °C
    QualificationAEC-Q101
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1277

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data ELX1277. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    The Figures Explained

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    At 18 A the clamp sits at 16.7 V, or 3.34 times the 5 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    150 pF per line is 1.1 ohms of reactance at 1 GHz and 10.6 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 5 V the part draws at most 1 uA, which is 5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    All 2 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.

    The STS series is a diode array in a three to eight pin package: one die per line, all of them sharing a common ground pin. The working voltage is set by the process, not by a resistor divider, so the part either sits above the bus level or it does not belong on that bus at all.

    Placement in the Circuit

    On a multi-line bus, put one array at the connector rather than one part per line spread along the board. The lines then share a single ground inductance, and the clamps stay within a few millivolts of each other during the event.

    • The standoff voltage is a DC figure. A bus that idles at 5 V and swings to 12 V in a fault needs a part rated above 12 V, not above 5 V, or the array conducts on every fault and fails open.
    • Peak pulse power is an 8/20 microsecond figure per line. A longer waveform allows less current and a shorter one more; the derating curve in the data sheet converts between them and is the number to use when the surge is not the standard one.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.

    How many of these parts survive repeated strikes?
    The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.