| Parameter | Value |
|---|---|
| Orderable part number | STS232050UL40 |
| Standoff voltage (VRWM) | 5 V |
| Breakdown voltage (min / typ / max) | 7 V / 8 V / 9 V |
| Leakage current at VRWM | 100 uA max |
| Peak pulse power, 8/20 us, per line | 60 W |
| Clamping voltage at 1 A | 11 V |
| Clamping voltage at 4 A | 15 V |
| Junction capacitance at 1 MHz, per line | 0.4 pF typ / 0.65 pF max |
| Channels | 2 |
| Polarity | Unidirectional |
| ESD capability, IEC 61000-4-2 | +/-20 kV contact / +/-20 kV air |
| Package | SOT-23 (S23) |
| Mounting | Surface mount |
| Moisture sensitivity level | MSL 3 |
| Operating junction temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11155 |
The outline drawing, pad geometry, derating curves and the pulse
waveform are on the pages of Eaton Technical Data 11155. Values above are
read directly from the electrical table for this part number, not from the family
summary.
A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.
At 4 A the clamp sits at 15 V, or 3.00 times the 5 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 60 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.
0.4 pF per line is 398 ohms of reactance at 1 GHz and 3,979 ohms at 100 MHz. Low enough that the loading can be ignored on a high speed pair, which is what this capacitance grade is sold for.
Standing at 5 V the part draws at most 100 uA, which is 500 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.
All 2 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.
The STS series is a diode array in a three to eight pin package: one die per line, all of them sharing a common ground pin. The working voltage is set by the process, not by a resistor divider, so the part either sits above the bus level or it does not belong on that bus at all.
Keep the return current under the signal. A discharge leaves through the ground pin, and if that current has to cross the board to find a plane it will couple into everything it passes on the way.
How is the working voltage chosen?
Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.
Can one package protect several lines?
Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.
What happens if the surge exceeds the rating?
The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.