Eaton STS232360U261 ESD Suppressor 36 V 26 pF
Eaton STS232360U261 ESD Suppressor 36 V 26 pF

Eaton STS232360U261 ESD Suppressor 36 V 26 pF

Share
STS232360U261: 36 V standoff TVS diode array, 2-channel, 26 pF per line, SOT-23 (S23), commercial grade.
    • Product Details
    • Download

    Eaton STS232360U261 ESD Suppressor 36 V 26 pF

    STS232360U261 at a glance: TVS diode array ESD suppressor, 36 V standoff, 75 V clamp, 2 channels, 26 pF, 350 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberSTS232360U261
    Standoff voltage (VRWM)36 V
    Breakdown voltage (min / typ / max)40 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line350 W
    Clamping voltage at 1 A60 V
    Clamping voltage at 4 A75 V
    Junction capacitance at 1 MHz, per line26 pF typ
    Channels2
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-8 kV contact / +/-15 kV air
    PackageSOT-23 (S23)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11148

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11148. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    Reading the Data Sheet

    The STS series is a diode array in a three to eight pin package: one die per line, all of them sharing a common ground pin. The working voltage is set by the process, not by a resistor divider, so the part either sits above the bus level or it does not belong on that bus at all.

    At 4 A the clamp sits at 75 V, or 2.08 times the 36 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    26 pF per line is 6.1 ohms of reactance at 1 GHz and 61.2 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 36 V the part draws at most 1 uA, which is 36 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    All 2 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    Layout and Placement

    Keep the return current under the signal. A discharge leaves through the ground pin, and if that current has to cross the board to find a plane it will couple into everything it passes on the way.

    • A unidirectional array clamps one polarity at the breakdown and the other at a forward drop. That asymmetry is correct on a DC rail and wrong on a differential pair that swings below ground.
    • Breakdown is specified at 1 mA. The spread between minimum and maximum is production tolerance, so the design margin is measured from the minimum, not the typical.

    Frequently Asked Questions

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    Why does the package affect the rating?
    It sets the thermal mass and the lead inductance. The same die in a SOD-523 and a SOT-23 dissipates differently, so the package is part of the electrical choice rather than only a footprint decision.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.