Eaton STS321033U202 ESD Suppressor 3.3 V 200 pF
Eaton STS321033U202 ESD Suppressor 3.3 V 200 pF

Eaton STS321033U202 ESD Suppressor 3.3 V 200 pF

Share
STS321033U202: 3.3 V standoff TVS diode array, 1-channel, 200 pF per line, SOD-323 (S32), commercial grade.
    • Product Details
    • Download

    Eaton STS321033U202 ESD Suppressor 3.3 V 200 pF

    STS321033U202 at a glance: TVS diode array ESD suppressor, 3.3 V standoff, 6.5 V clamp, 1 channel, 200 pF, 350 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberSTS321033U202
    Standoff voltage (VRWM)3.3 V
    Breakdown voltage (min / typ / max)4 V
    Leakage current at VRWM5 uA max
    Peak pulse power, 8/20 us, per line350 W
    Clamping voltage at 1 A6.5 V
    Junction capacitance at 1 MHz, per line200 pF typ / 250 pF max
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11152

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11152. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    Reading the Data Sheet

    A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.

    At 1 A the clamp sits at 6.5 V, or 1.97 times the 3.3 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    200 pF per line is 0.8 ohms of reactance at 1 GHz and 8.0 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 3.3 V the part draws at most 5 uA, which is 16.5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    Layout and Placement

    On a multi-line bus, put one array at the connector rather than one part per line spread along the board. The lines then share a single ground inductance, and the clamps stay within a few millivolts of each other during the event.

    • The standoff voltage is a DC figure. A bus that idles at 5 V and swings to 12 V in a fault needs a part rated above 12 V, not above 5 V, or the array conducts on every fault and fails open.
    • Peak pulse power is an 8/20 microsecond figure per line. A longer waveform allows less current and a shorter one more; the derating curve in the data sheet converts between them and is the number to use when the surge is not the standard one.

    Frequently Asked Questions

    How many of these parts survive repeated strikes?
    The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.