Eaton STS321050B100AH TVS Diode 5 V 400 W
Eaton STS321050B100AH TVS Diode 5 V 400 W

Eaton STS321050B100AH TVS Diode 5 V 400 W

Share
STS321050B100AH: 5 V standoff TVS diode array, 1-channel, 1 pF per line, SOD-323 (S32), AEC-Q101.
    • Product Details
    • Download

    Eaton STS321050B100AH TVS Diode 5 V 400 W

    STS321050B100AH at a glance: TVS diode array ESD suppressor, 5 V standoff, 9.8 V clamp, 1 channel, 1 pF, 400 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSTS321050B100AH
    Standoff voltage (VRWM)5 V
    Breakdown voltage (min / typ / max)6 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line400 W
    Clamping voltage at 1 A9.8 V
    Junction capacitance at 1 MHz, per line1 pF typ / 1.5 pF max
    Channels1
    PolarityBidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 1
    Operating junction temperature-55 °C to +150 °C
    QualificationAEC-Q101
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1278

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data ELX1278. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    The Figures Explained

    Eaton builds these on a silicon avalanche process, so the clamp is sharp and the part recovers without the off-state drift a metal oxide varistor shows after a surge. The trade is a fixed breakdown window that the working voltage has to sit below with margin.

    At 1 A the clamp sits at 9.8 V, or 1.96 times the 5 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 400 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    1 pF per line is 159 ohms of reactance at 1 GHz and 1,592 ohms at 100 MHz. Low enough that the loading can be ignored on a high speed pair, which is what this capacitance grade is sold for.

    Standing at 5 V the part draws at most 1 uA, which is 5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    Placement in the Circuit

    Run the protected line through the pad rather than teeing off it. A stub of a few millimetres leaves a reflection that shows up as an eye closure on a fast pair and as a harmless glitch on a slow one, and the same layout serves both.

    • A unidirectional array clamps one polarity at the breakdown and the other at a forward drop. That asymmetry is correct on a DC rail and wrong on a differential pair that swings below ground.
    • Peak pulse power is an 8/20 microsecond figure per line. A longer waveform allows less current and a shorter one more; the derating curve in the data sheet converts between them and is the number to use when the surge is not the standard one.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    Is the automotive suffix a different die?
    It is the same function qualified to AEC-Q101 with a wider tested temperature range and a moisture sensitivity level of 1 instead of 3. The electrical table is repeated per part number because the clamp and capacitance differ between them.