Eaton STS321050B331 ESD Suppressor 5 V 33 pF
Eaton STS321050B331 ESD Suppressor 5 V 33 pF

Eaton STS321050B331 ESD Suppressor 5 V 33 pF

Share
STS321050B331: 5 V standoff TVS diode array, 1-channel, 33 pF per line, SOD-323 (S32), commercial grade.
    • Product Details
    • Download

    Eaton STS321050B331 ESD Suppressor 5 V 33 pF

    STS321050B331 at a glance: TVS diode array ESD suppressor, 5 V standoff, 18 V clamp, 1 channel, 33 pF, 400 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberSTS321050B331
    Standoff voltage (VRWM)5 V
    Breakdown voltage (min / typ / max)5.5 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line400 W
    Clamping voltage at 1 A9 V
    Clamping voltage at 22 A18 V
    Junction capacitance at 1 MHz, per line33 pF typ / 75 pF max
    Channels1
    PolarityBidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11151

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11151. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    Reading the Data Sheet

    Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.

    At 22 A the clamp sits at 18 V, or 3.60 times the 5 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 400 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    33 pF per line is 4.8 ohms of reactance at 1 GHz and 48.2 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 5 V the part draws at most 1 uA, which is 5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    The STS series is a diode array in a three to eight pin package: one die per line, all of them sharing a common ground pin. The working voltage is set by the process, not by a resistor divider, so the part either sits above the bus level or it does not belong on that bus at all.

    Layout and Placement

    Run the protected line through the pad rather than teeing off it. A stub of a few millimetres leaves a reflection that shows up as an eye closure on a fast pair and as a harmless glitch on a slow one, and the same layout serves both.

    • The clamping voltage is quoted at one pulse current. Halve the current and the clamp falls by roughly the dynamic resistance times the current, which is why a part chosen for a small surge looks better than its headline number.
    • Leakage is quoted at the rated voltage and at 25 °C. It roughly doubles every 10 °C, which matters on a rail that sits hot inside an enclosure.

    Frequently Asked Questions

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.

    How many of these parts survive repeated strikes?
    The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.

    Can one package protect several lines?
    Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.

    Shenzhen Gaorunxin Technology Co., Ltd